Experimental Study on Triaxial Compressive Mechanical Properties of Polypropylene Fiber Coral Seawater Concrete
Hang Shi1, Linlin Mo1, Mingyan Pan1
1College of Civil Engineering and Architecture, Guangxi University, Nanning 530004, China.
Abstract:
In order to study the mechanical properties of polypropylene fiber all-coral seawater concrete in triaxial compression, 36 specimens were developed and constructed for triaxial compression load testing employing confining pressure value (0, 6, 12, 18 MPa) and polypropylene fiber admixture (1 kg·m-3, 2 kg·m-3, 3 kg·m-3) as variation parameters. The test observed the failure mode of the specimen and obtained the stress-strain curve of the whole process of its force damage failure. An in-depth analysis of polypropylene fiber all-coral seawater concrete's peak stress, peak strain, initial elastic modulus, axial deflection, energy dissipation, ductility, and damage evolution process was carried out based on the experimental data. The test findings indicated that the best effect on the deformation properties of polypropylene fiber all-coral seawater concrete is obtained when 3 kg·m-3 of polypropylene fiber is blended. Under triaxial compression, the correct number of polypropylene fibers may significantly enhance the peak stress, peak strain, ductility, and elastic modulus of polypropylene fiber all-coral seawater concrete, therefore enhancing the brittle characteristics of coral concrete. During the triaxial surround pressure test, the confining pressure value and polypropylene fiber coupling effect delayed the appearance of initial damage in polypropylene fiber complete coral seawater concrete specimens, slowed the development of damage, and reduced the degree of damage to the specimens.
Related Concept Videos
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Relation Between Tensile Strength and Compressive Strength of Concrete
Fiber Reinforced Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Impact Strength of Concrete