Related Experiment Video
Updated: Sep 6, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Temporal and spatial pacemap parameters for identification of cardiac surfaces with critical sites for ventricular
Akiko Ueda1, Yumi Katsume2, Yosuke Miwa2
1Division of Advanced Arrhythmia Management, Kyorin University Hospital, Mitaka, Tokyo, Japan.
Introduction:
Multisurface pacemapping may help identify the surface of interest in scar-related ventricular tachycardia (VT). This study aimed to investigate the performance of pacemap parameters for detecting critical sites through multisurface mapping.
Methods And Results:
In 26 patients who underwent scar-related VT ablation, pacemap parameters including a matching score, the difference between the longest and shortest stimulus-QRS intervals (Δs-QRS), and the distance between the good pacemap sites were measured. The parameters were compared between surfaces with and without critical sites and ablation outcomes. A total of 941 pacemap at 56 surfaces targeting 35 VTs were analyzed. A greater Δs-QRS (40 vs. 8 ms, p < .001) and longer distance between two good pacemap sites (24 vs. 13 mm, p < .001) were observed on the surfaces with critical sites. A similar trend was seen in multisurface pacemapping for the same VTs (52 vs. 18 ms in Δs-QRS, p = .021; 37 vs. 12 mm in distance, p = .019), although the best pacemap scores were comparable (94 vs. 87, p = .295). The Δs-QRS > 20 ms and the distance >19 mm showed high positive likelihood ratios (19.8 and 6.1, respectively) for discriminating the surface harboring the critical site. Ablation of VTs fulfilling these parameters was successful on the surfaces, but without the required multisurface ablation.
Conclusion:
Temporal (Δs-QRS) and spatial (distance) parameters for good pacemap match sites were excellent markers for detecting the surface harboring critical sites in scar-related VT. A multisurface pacemapping can successfully identify the surface of interest.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
09:24Multiparametric Optical Mapping of the Langendorff-perfused Rabbit Heart
Published on: September 13, 2011
Related Concept Videos
Dysrhythmias III: Characteristics of Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias