Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Relative Motion Analysis using Rotating Axes-Problem Solving01:29

Relative Motion Analysis using Rotating Axes-Problem Solving

445
Consider a crane whose telescopic boom rotates with an angular velocity of 0.04 rad/s and angular acceleration of 0.02 rad/s2. Along with the rotation, the boom also extends linearly with a uniform speed of 5 m/s. The extension of the boom is measured at point D, which is measured with respect to the fixed point C on the other end of the boom. For the given instant, the distance between points C and D is 60 meters.
Here, in order to determine the magnitude of velocity and acceleration for point...
445
Relative Motion Analysis using Rotating Axes01:25

Relative Motion Analysis using Rotating Axes

527
Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame.
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
527
Absolute Motion Analysis- General Plane Motion01:24

Absolute Motion Analysis- General Plane Motion

269
Visualize a drone, with its propellers spinning rapidly, hovering mid-air. The fascinating movements and operations of this drone can be comprehended by applying the principle of general plane motion.
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
269
Curvilinear Motion: Rectangular Components01:23

Curvilinear Motion: Rectangular Components

610
Curvilinear motion characterizes the movement of a particle or object along a curved path, notably evident when envisioning a car navigating a winding road. If the car starts at point A, its position vector is established within a fixed frame of reference, where the ratio of the position vector to its magnitude signifies the unit vector pointing in the position vector's direction.
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
610
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

6.6K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
6.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Multivariate associations between sleep patterns and self-regulation in adolescence: Canonical correlation analysis across ABCD and NCANDA cohorts.

Chronobiology international·2026
Same author

Selenium in Agricultural Products: Advances in Detection of Total Content and Speciation.

Foods (Basel, Switzerland)·2026
Same author

Leveraging Machine Learning to Advance Alcohol Research: Current Applications, Challenges, and Opportunities.

Alcohol research : current reviews·2026
Same author

A framework of digital biomarkers for neurodegenerative diseases.

Nature reviews bioengineering·2026
Same author

Mapping Individualized Developmental Imbalance in Youth and Its Association with Psychopathology.

bioRxiv : the preprint server for biology·2026
Same author

Using deep learning to identify brain networks mediating cognitive and motor impairments in alcohol use disorder.

Translational psychiatry·2026
Same journal

Cycle Diffusion Model for Counterfactual Image Generation.

Predictive Intelligence in Medicine. PRIME (Workshop)·2026
Same journal

Neurocognitive Latent Space Regularization for Multi-Label Diagnosis from MRI.

Predictive Intelligence in Medicine. PRIME (Workshop)·2025
Same journal

Spectral Graph Sample Weighting for Interpretable Sub-cohort Analysis in Predictive Models for Neuroimaging.

Predictive Intelligence in Medicine. PRIME (Workshop)·2024
Same journal

SynthA1c: Towards Clinically Interpretable Patient Representations for Diabetes Risk Stratification.

Predictive Intelligence in Medicine. PRIME (Workshop)·2024
Same journal

Imputing Brain Measurements Across Data Sets via Graph Neural Networks.

Predictive Intelligence in Medicine. PRIME (Workshop)·2023
Same journal

Bridging the Gap between Deep Learning and Hypothesis-Driven Analysis via Permutation Testing.

Predictive Intelligence in Medicine. PRIME (Workshop)·2022
See all related articles

Related Experiment Video

Updated: Sep 6, 2025

Optogenetic Functional MRI
06:06

Optogenetic Functional MRI

Published on: April 19, 2016

14.9K

Adversarial Bayesian Optimization for Quantifying Motion Artifact Within MRI.

Anastasia Butskova1, Rain Juhl1, Dženan Zukić2

  • 1Stanford University, Stanford, CA, USA.

Predictive Intelligence in Medicine. PRIME (Workshop)
|June 24, 2022
PubMed
Summary
This summary is machine-generated.

This study introduces an automated computational tool to measure the severity of movement-related blurring and ghosting in brain scans. By using a specialized machine learning approach to simulate realistic movement patterns, the researchers created a reliable system that outperforms traditional manual or simple mathematical methods for assessing scan quality.

Keywords:
neuroimaging quality controlimage artifact detectionregression modelingautomated scan assessment

Frequently Asked Questions

More Related Videos

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.7K
Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
08:19

Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences

Published on: May 17, 2018

9.9K

Related Experiment Videos

Last Updated: Sep 6, 2025

Optogenetic Functional MRI
06:06

Optogenetic Functional MRI

Published on: April 19, 2016

14.9K
Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.7K
Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
08:19

Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences

Published on: May 17, 2018

9.9K

Area of Science:

  • Medical imaging and Adversarial Bayesian Optimization within neuroinformatics
  • Radiological diagnostics and computational neuroscience

Background:

Subject movement during magnetic resonance imaging often creates severe image degradation that complicates clinical interpretation. This phenomenon manifests as ghosting patterns or widespread noise, which frequently compromises the integrity of neuroimaging datasets. Prior research has shown that relying on human visual assessment is both costly and prone to significant observer bias. No prior work had resolved the difficulty of obtaining precise, fine-grained labels for these complex image distortions. That uncertainty drove the development of automated systems to standardize quality assessment across large-scale studies. Existing mathematical metrics often fail to capture the nuanced relationship between physical movement and resulting visual artifacts. This gap motivated the creation of more robust computational frameworks capable of handling diverse scanning conditions. The current literature lacks a unified approach to quantify these distortions without requiring extensive manual annotation by trained radiologists.

Purpose Of The Study:

The primary aim of this study is to develop an automated framework for quantifying the severity of motion artifacts in brain magnetic resonance imaging. Researchers sought to address the limitations of current quality control methods that rely on expensive and subjective human visual inspection. The project specifically targets the challenge of missing fine-grained ground-truth labels for image distortion levels. To overcome this, the team formulated the task as a regression problem using a large-scale dataset. They intended to create a system that could infer underlying movement parameters like rotation and translation from acquired scan data. By injecting synthetic artifacts into clean images, the authors aimed to generate a robust training set for their regressor. This effort was motivated by the need to improve the reliability of neuroimaging findings in large-scale adolescent studies. Ultimately, the study seeks to provide a more consistent and objective metric for assessing scan quality compared to existing mathematical criteria.

Main Methods:

The investigators designed a regression-based framework to automatically estimate the intensity of movement-related image corruption. They utilized a specialized statistical technique to infer hidden rotation and translation variables from existing scan data. This review approach involved generating synthetic distortions by sampling from these inferred movement distributions. These simulated artifacts were then injected into high-quality, clean brain images to create a comprehensive training set. The team trained their regressor using this diverse collection of synthetic examples to ensure robust performance. They validated the resulting model by applying it to a large cohort of 990 scans from a national adolescent study. The researchers compared their automated output against traditional metrics like the Entropy Focus Criterion. Finally, they evaluated the consistency of their results against manually assigned binary quality labels to confirm superior reliability.

Main Results:

The automated framework successfully produced motion scores that demonstrated higher reliability than traditional assessment techniques. The researchers applied their model to 990 brain scans obtained from the National Consortium on Alcohol and Neurodevelopment in Adolescence. Their findings revealed that the derived motion levels provided a more accurate reflection of image quality than the Entropy Focus Criterion. Furthermore, the approach outperformed manually defined binary labels in distinguishing between varying degrees of artifact severity. The regression model effectively learned to quantify distortions by training on synthetic data generated through the proposed optimization strategy. This method successfully resolved the challenge of missing ground-truth labels by creating high-fidelity simulated training examples. The results indicate that the system maintains high performance across a large and diverse neuroimaging dataset. These findings confirm that the framework offers a scalable and objective alternative to subjective visual inspection methods.

Conclusions:

The researchers demonstrate that their proposed framework provides a more consistent measure of image quality than established benchmarks. This synthesis suggests that automated regression models can effectively replace subjective visual inspection in large neuroimaging cohorts. The study implies that synthetic data generation remains a viable strategy for training models when precise ground-truth labels are unavailable. Their findings indicate that the derived motion scores correlate better with actual scan quality than the Entropy Focus Criterion. The authors conclude that their approach offers a scalable solution for managing data quality in multi-site brain imaging projects. This work highlights the potential for advanced statistical inference to mitigate the negative impacts of patient movement on diagnostic accuracy. The evidence supports the integration of these automated tools into standard preprocessing pipelines for pediatric and adolescent neuroimaging. These results provide a foundation for future efforts to refine quality control protocols in clinical and research settings.

The researchers propose Adversarial Bayesian Optimization to estimate rotation and translation parameters. This mechanism allows the system to infer underlying movement distributions, which are then used to inject realistic synthetic artifacts into clean brain scans for training the regression model.

The framework utilizes a regression model trained on synthetic data. This approach overcomes the lack of fine-grained ground-truth labels by creating a diverse dataset of simulated movement patterns derived from the National Consortium on Alcohol and Neurodevelopment in Adolescence collection.

A large-scale dataset of 990 brain scans from the National Consortium on Alcohol and Neurodevelopment in Adolescence is necessary. This volume of data ensures the model can generalize across various imaging conditions and capture subtle variations in artifact intensity.

The synthetic data acts as a proxy for real-world movement. By sampling from inferred distributions, the researchers create controlled training examples that allow the regressor to learn the relationship between physical parameters and visual image degradation.

The researchers measure the reliability of their derived motion scores against the Entropy Focus Criterion and manual binary labels. Their results indicate that the new approach provides a more consistent and accurate quantification of artifact levels across the entire cohort.

The authors propose that their method significantly reduces the reliance on expensive human expert review. They claim this automated strategy improves the reliability of neuroimaging findings by standardizing how researchers identify and exclude low-quality scans from subsequent statistical analyses.