Higher-order regression three-dimensional motion-compensation method for real-time optical coherence tomography
Ruizhi Zuo1, Kristina Irsch2,3, Jin U Kang1,3
1Johns Hopkins University, Whiting School of Engineering, Baltimore, Maryland, United States.
Significance:
Optical coherence tomography (OCT) allows high-resolution volumetric three-dimensional (3D) imaging of biological tissues in vivo. However, 3D-image acquisition can be time-consuming and often suffers from motion artifacts due to involuntary and physiological movements of the tissue, limiting the reproducibility of quantitative measurements.
Aim:
To achieve real-time 3D motion compensation for corneal tissue with high accuracy.
Approach:
We propose an OCT system for volumetric imaging of the cornea, capable of compensating both axial and lateral motion with micron-scale accuracy and millisecond-scale time consumption based on higher-order regression. Specifically, the system first scans three reference B-mode images along the C-axis before acquiring a standard C-mode image. The difference between the reference and volumetric images is compared using a surface-detection algorithm and higher-order polynomials to deduce 3D motion and remove motion-related artifacts.
Results:
System parameters are optimized, and performance is evaluated using both phantom and corneal (ex vivo) samples. An overall motion-artifact error of <4.61 microns and processing time of about 3.40 ms for each B-scan was achieved.
Conclusions:
Higher-order regression achieved effective and real-time compensation of 3D motion artifacts during corneal imaging. The approach can be expanded to 3D imaging of other ocular tissues. Implementing such motion-compensation strategies has the potential to improve the reliability of objective and quantitative information that can be extracted from volumetric OCT measurements.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Imaging Studies III: Computed Tomography
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Curvilinear Motion: Polar Coordinates
The particle's location is described using a unit vector along the radial direction. Deriving the particle's position...