Related Experiment Video
Updated: Sep 6, 2025

Measurement of Heme Synthesis Levels in Mammalian Cells
Published on: July 9, 2015
A case of congenital methaemoglobinaemia with secondary polycythemia
Shamsa Kanwal1, Muhammad Aamir2, Sobia Irum1
1Department of Chemical Pathology, Armed Forces Institute of Pathology, Rawalpindi, Pakistan.
Haemoglobin contains iron in a ferrous form. When the iron is oxidized, it is called Methaemoglobin (MetHb). MetHb leads to tissue hypoxia, cyanosis, and secondary polycythemia. Methaemoglobinaemia is acquired or congenital. In this case, a 22-years-old male patient presented with cyanosis, headache, and lack of concentration. Cyanosis was present since birth. His previous investigations showed polycythemia. He was misdiagnosed on multiple occasions and was undergoing venesections for polycythemia. On evaluation at a private clinic, an Oxygen saturation gap was noted between the results of the pulse oximeter and arterial blood gas analyzer. This raised suspicion on the presence of MetHb. He was referred to Armed Forces Institute of Pathology, Rawalpindi for further workup.The sample obtained for MetHb was chocolate brown in colour. Analysis was done via co-oximetry. A high level of MetHb (45.6%) was obtained. All other radiological and haematological investigations were in the normal range. On the basis of history, clinical presentation, and investigations, he was diagnosed as a case of congenital methaemoglobinaemia with secondary polycythemia.
Haemoglobin contains iron in a ferrous form. When the iron is oxidized, it is called Methaemoglobin (MetHb). MetHb leads to tissue hypoxia, cyanosis, and secondary polycythemia. Methaemoglobinaemia is acquired or congenital. In this case, a 22-years-old male patient presented with cyanosis, headache, and lack of concentration. Cyanosis was present since birth. His previous investigations showed polycythemia. He was misdiagnosed on multiple occasions and was undergoing venesections for polycythemia. On evaluation at a private clinic, an Oxygen saturation gap was noted between the results of the pulse oximeter and arterial blood gas analyzer. This raised suspicion on the presence of MetHb. He was referred to Armed Forces Institute of Pathology, Rawalpindi for further workup.The sample obtained for MetHb was chocolate brown in colour. Analysis was done via co-oximetry. A high level of MetHb (45.6%) was obtained. All other radiological and haematological investigations were in the normal range. On the basis of history, clinical presentation, and investigations, he was diagnosed as a case of congenital methaemoglobinaemia with secondary polycythemia.
Related Concept Videos
Disorders of Erythrocytes
Erythrocyte disorders can be broadly categorized into two main types: anemic and polycythemic conditions.
A low oxygen-carrying capacity of the blood due to the loss, lower production, or destruction of erythrocytes is termed anemia. Hemorrhagic anemia, for example, occurs when bleeding from an external wound or internal ulcer reduces erythrocyte counts.
On the other...
Inborn Errors of Metabolism
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
Oxygen Transport in the Blood
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Multiple Allele Traits

