Thermography as an aid for the complementary diagnosis of nodules in the thyroid gland
Viviane Magas Bittencourt de Camargo1, Leandra Ulbricht2, Jose Carlos Pereira Coninck3
1Federal Technological University of Paraná/Graduate Program in Electrical Engineering and Industrial Informatics, Endereço: Av. Sete de Setembro 3165. Campus Curitiba Sede Centro, Curitiba, PR, CEP-80230-901, Brazil. vivianemagas@hotmail.com.
Background:
Considering the estimate that thyroid cancer will become the fourth most prevalent type of tumor, improving its diagnosis is a necessity. The gold standard for evaluating thyroid nodules is ultrasound followed by biopsy. These tests, however, have limitations, especially in nodules smaller than 0.5 cm. Dynamic infrared thermography is an imaging method that does not require ionizing radiation or contrast injection. The aim of the study was to analyze the thermal behavior of thyroid nodules through infrared thermography using the cold stress protocol.
Results:
The Wilcoxon test showed thermal differences between groups (control and healthy, p < 0.001). The difference in the thermal behavior of the nodular tissues was evidenced by the longitudinal analysis. When comparing the nodules, it was possible to verify that the beginnings of tissue heating is significant (p = 0.001). In addition, the variability analysis showed a "well" effect, which occurred in period t-1 (pre-cooling time) to period t = 3 (time three minutes). Benign nodules had a variation ratio of 1.81 compared to malignant nodules.
Conclusion:
Benign nodules present a different thermal behavior than malignant nodules, and both present different behavior than normal tissue. For the analysis of nodules, the protocol used with cold stress, dynamic thermography and the inclusion of time t-1 were essential for the differentiation of nodules in the thyroid gland. Therefore, we recommend the continuance of these parameters for future studies.
Methods:
Thirty-three individuals with nodules in the thyroid region and nine healthy individuals participated in this descriptive exploratory study. In total, 42 nodules were evaluated, 11 malignant and 31 benign. The region of interest was exposed to cold stress for 30 s. First, the image was captured before the cold stress and subsequently, the images were assessed every 30 s, over a 10-min time period after cold stress. The perfusion and the thermal behavior of the tissues were evaluated by longitudinal analysis based on the number of pixels in each time period. The statistical tests of Wilcoxon, F-Snedecor and longitudinal models would assist in data analysis.
Related Concept Videos
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Synthesis and Regulation of Thyroid Hormones
Upon reaching the thyroid gland, TSH stimulates the follicular cells' active uptake of iodide ions from the blood. The ions diffuse to the apical surface of the cells and are oxidized to iodine. The...
Radiological Investigation I: X-ray and CT
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...