Related Experiment Video
Updated: Sep 6, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Kirigami-Inspired Pressure Sensors for Wearable Dynamic Cardiovascular Monitoring
Keyu Meng1,2, Xiao Xiao2, Zixiao Liu3
1School of Electronic and Information Engineering, Jilin Provincial Key Laboratory of Human Health Status Identification and Function Enhancement, Changchun University, Changchun, 130022, China.
Abstract:
Continuously and accurately monitoring pulse-wave signals is critical to prevent and diagnose cardiovascular diseases. However, existing wearable pulse sensors are vulnerable to motion artifacts due to the lack of proper adhesion and conformal interface with human skin during body movement. Here, a highly sensitive and conformal pressure sensor inspired by the kirigami structure is developed to measure the human pulse wave on different body artery sites under various prestressing pressure conditions and even with body movement. COMSOL multiphysical field coupling simulation and experimental testing are used to verify the unique advantages of the kirigami structure. The device shows a superior sensitivity (35.2 mV Pa-1 ) and remarkable stability (>84 000 cycles). Toward practical applications, a wireless cardiovascular monitoring system is developed for wirelessly transmitting the pulse signals to a mobile phone in real-time, which successfully distinguished the pulse waveforms from different participants. The pulse waveforms measured by the kirigami inspired pressure sensor are as accurate as those provided by the commercial medical device. Given the compelling features, the sensor provides an ascendant way for wearable electronics to overcome motion artifacts when monitoring pulse signals, thus representing a solid advancement toward personalized healthcare in the era of the Internet of Things.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure

