[Current situation and problems of extracorporeal membrane oxygenation use in China]

X Zhou1

  • 1Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, China National Critical Care Quality Control Center, ECMO Quality Improvement Action (EQIA) Study Group, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing 100710, China Information Center Department/Department of Information Management, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College & Chinese Academy of Medical Sciences, Beijing 100710, China.

Related Concept Videos

Administering Oxygen by Mask01:30

Administering Oxygen by Mask

Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
729
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen01:16

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen

Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
933
Acute Respiratory Failure-IV01:23

Acute Respiratory Failure-IV

Respiratory failure can manifest suddenly or gradually, characterized by a rapid decline in PaO2 and a rapid rise in PaCO2. This situation indicates a severe respiratory problem that may quickly become a life-threatening emergency. One of the early signs of hypoxemic Acute Respiratory Failure (ARF) is a change in mental status due to the brain's sensitivity to oxygen levels and changes in acid-base balance. Symptoms such as restlessness, confusion, and agitation suggest inadequate oxygen...
218
Acute Respiratory Failure-II01:21

Acute Respiratory Failure-II

Type I Respiratory Failure, or hypoxemic respiratory failure, occurs when the partial pressure of oxygen (PaO2) in arterial blood falls below 60 mmHg while breathing room air without a corresponding increase in arterial carbon dioxide levels (PaCO2). This condition highlights a significant impairment in the lungs' capacity to oxygenate the blood.
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
343
Acute Respiratory Failure-V01:29

Acute Respiratory Failure-V

The treatment for acute respiratory failure varies based on factors like the underlying cause, overall health, and severity. A collaborative healthcare team is essential for early detection, often through arterial blood gas analysis. Identifying the cause is the primary goal, with treatment strategies adjusted for ventilation/perfusion (V/Q) mismatch, shunting, or diffusion impairment.
Ensure that patients are monitored continuously for their response to therapy, including changes in...
193
Oxygen Delivering System I: Nasal Cannula and Face Mask01:26

Oxygen Delivering System I: Nasal Cannula and Face Mask

The human body requires oxygen to function, and when the natural process of respiration is hindered, external devices, including the following, are needed to help deliver this vital gas.
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
567