Adam James1, Ross Foley1, Helene Murchan1
1Department of Paediatric Cardiology, CHI Crumlin, Dublin 12, Ireland.
Abstract:
A 20-month-old girl presented with severe dilated cardiomyopathy and decompensated congestive cardiac failure. Despite escalating inotropic and mechanical ventilation support, she required placement on extracorporeal membrane oxygenation and transfer to the transplant centre in Newcastle, England. She was placed on biventricular assist device and then Berlin Heart but failed to show any recovery of ventricular function. She underwent orthotopic heart transplantation at 2 years of age. She developed bacterial endocarditis with Enterococcus faecalis resulting in severe aortic valve regurgitation requiring aortic valve replacement with a 19 mm On-X valve (Airtivion) 11 days after her transplant. Given the size of the donor heart, it was possible to implant a 19-mm valve in this 12 kg child with minimal risk of patient prosthesis mismatch. She was anticoagulated with warfarin (On-X valve INR 2-3 for first 3 months; INR 1.5-2.0 thereafter). Although she suffered several other post-operative complications, including malabsorption, nasojejunal feeding, liver dysfunction, vertebral fractures, renal impairment and renal calcification, and need for repeat opening of her tracheostomy site following her initial decannulation, her aortic valve function has remained stable.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
11:20A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022