Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies
Published on: December 15, 2023
Fully Automated MRI Segmentation and Volumetric Measurement of Intracranial Meningioma Using Deep Learning
Ho Kang1, Joseph Nathanael Witanto2, Kevin Pratama2
1Department of Neurosurgery, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
Background:
Accurate and rapid measurement of the MRI volume of meningiomas is essential in clinical practice to determine the growth rate of the tumor. Imperfect automation and disappointing performance for small meningiomas of previous automated volumetric tools limit their use in routine clinical practice.
Purpose:
To develop and validate a computational model for fully automated meningioma segmentation and volume measurement on contrast-enhanced MRI scans using deep learning.
Study Type:
Retrospective.
Population:
A total of 659 intracranial meningioma patients (median age, 59.0 years; interquartile range: 53.0-66.0 years) including 554 women and 105 men.
Field Strength/Sequence:
The 1.0 T, 1.5 T, and 3.0 T; three-dimensional, T1 -weighted gradient-echo imaging with contrast enhancement.
Assessment:
The tumors were manually segmented by two neurosurgeons, H.K. and C.-K.P., with 10 and 26 years of clinical experience, respectively, for use as the ground truth. Deep learning models based on U-Net and nnU-Net were trained using 459 subjects and tested for 100 patients from a single institution (internal validation set [IVS]) and 100 patients from other 24 institutions (external validation set [EVS]), respectively. The performance of each model was evaluated with the Sørensen-Dice similarity coefficient (DSC) compared with the ground truth.
Statistical Tests:
According to the normality of the data distribution verified by the Shapiro-Wilk test, variables with three or more categories were compared by the Kruskal-Wallis test with Dunn's post hoc analysis.
Results:
A two-dimensional (2D) nnU-Net showed the highest median DSCs of 0.922 and 0.893 for the IVS and EVS, respectively. The nnU-Nets achieved superior performance in meningioma segmentation than the U-Nets. The DSCs of the 2D nnU-Net for small meningiomas less than 1 cm3 were 0.769 and 0.780 with the IVS and EVS, respectively.
Data Conclusion:
A fully automated and accurate volumetric measurement tool for meningioma with clinically applicable performance for small meningioma using nnU-Net was developed.
Evidence Level:
3 TECHNICAL EFFICACY: Stage 2.