Iodine/iodide-doped polymeric nanospheres for simultaneous voltammetric detection of p-aminophenol, phenol, and
Sabereh Narouie1, Gholam Hossein Rounaghi2, Hamideh Saravani3
1Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, P.O. Box 9177948974, Mashhad, Iran.
Abstract:
A sensor was developed for the first time based on polydopamine nanospheres doped with I2, I-, and IO3- species (PDA-Iodine), to determine the concentration of p-aminophenol (p-AP), phenol (Ph), and p-nitrophenol (p-NP) simultaneously. These polymeric nanospheres were successfully characterized using a variety of techniques including field emission scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, Fourier transform infrared, Raman spectroscopy, and X-ray diffraction analysis. A carbon paste electrode was modified with the PDA-Iodine (CPE/PDA-Iodine). Because of the electrocatalytic activity of DA/DQ, I2 and I- species (in the structure of PDA-Iodine), CPE/PDA-Iodine shows enhancement in the electrooxidation peak currents as well as slight negative shift in peak potentials of p-AP, Ph, and p-NP compared with a bare carbon paste electrode. Under optimal experimental conditions, the linear calibration plots are linear in the ranges 0.5-120 μM for p-AP, 0.7-120 μM for Ph, and 1.0-100 μM for p-NP with limits of detection of 30, 40, and 80 nM for p-AP, Ph, and p-NP, respectively (S/N = 3). To prove the performance of the method, the repeatability of the signals of CPE/PDA-Iodine was evaluated and the RSD values obtained were 2.9%, 3.2%, and 3.1% for p-AP (45 µM), Ph (40 µM), and p-NP (40 µM), respectively. The CPE/PDA-Iodine is a promising new sensor for sensing p-AP, Ph, and p-NP simultaneously in tap and river water sample and the values of recoveries for spiked samples were in the range 94.0-104.4%.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...