Can analyte protectants compensate wastewater matrix induced enhancement effects in gas chromatography - mass
Mathias B Jørgensen1, Jan H Christensen2
1BIOFOS A/S, Refshalevej 250, København 1432, Denmark; Analytical Chemistry Group, Department of Plant and Environmental Sciences, University of Copenhagen, Thorvaldsensvej 40, Frederiksberg C, 1871, Denmark.
Abstract:
This study aimed to investigate the ability of analyte protectants to enhance GC-MS signals and compensate matrix effects for a range of micropollutants in pure standard, effluent, and influent wastewater samples during analysis and detection. Wastewater samples were prepared for analysis using multilayer solid phase extraction for the purpose of extracting sample components with a broad range of physical-chemical properties. The sample extracts were either spiked or not spiked with target compounds and four analyte protectants: 3-ethoxy-1,2-propanediol, D-sorbitol, gluconolactone, and shikimic acid. In this way, it was possible to evaluate the matrix effects of wastewater samples and compare the use of analyte protectants with the conventional correction method of allocating a best matching internal standard to each target compound. A relation was observed between level of wastewater treatment and matrix effects, with the largest effects observed for influent samples and the smallest effects for effluent samples. Compensation of matrix effects with analyte protectants gave comparable results with the conventional correction method of allocating a best matching internal standard to each of the 13 investigated micropollutants. The best overall compensation was observed using analyte protectants and the internal standard correction method in combination.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...