Related Experiment Video
Updated: Sep 5, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
[Development and Validation of Dose Management Software in IVR Utilizing Radiation Information System]
Kazuya Mori1,2, Takuji Tsuchida1, Ryou Sekiguchi1
1Department of Radiological Technology, Saiseikai Kawaguchi General Hospital.
This study demonstrates the effectiveness of in-house developed dose management software for interventional radiology (IVR). The software significantly reduces analysis time and improves accuracy, supporting compliance with Japan diagnostic reference levels 2020 (DRLs 2020).
Area of Science:
- Medical Imaging and Radiology
- Radiation Dose Management
- Health Informatics
Background:
- Interventional radiology (IVR) relies on equipment display dose for dose management, aiming to comply with Japan diagnostic reference levels 2020 (DRLs 2020).
- Widespread adoption of dose management software utilizing radiation dose structured reports (RDSR) remains limited.
- Radiology information systems (RIS) offer potential for integrated dose management by recording procedures and lesions.
Purpose of the Study:
- To assess the utility of an in-house developed dose management software integrated with a radiology information system (RIS) for interventional radiology (IVR).
- To evaluate the software's ability to manage radiation doses in IVR procedures and ensure compliance with Japan diagnostic reference levels 2020 (DRLs 2020).
Main Methods:
- Analysis of 290 IVR cases (141 cardiac, 149 other regions) from July to September 2020.
- Evaluation of air kerma-area product, patient entrance reference point air kerma, and patient data (height, weight, BMI).
- Comparison of analysis time and accuracy between manual methods and the developed dose management software using paired t-tests.
Main Results:
- The in-house software significantly reduced analysis time for both cardiac (4180.25±1161.79s vs 36.25±15.32s) and other regions (4366.92±1393.19s vs 38.08±17.34s) (p<0.05).
- Analysis accuracy achieved was high, with 96.30% for cardiac and 98.89% for other regions.
- The software demonstrated efficient dose management capabilities within the IVR workflow.
Conclusions:
- The developed dose management software utilizing RIS is effective for interventional radiology.
- The software offers significant improvements in analysis time and accuracy for dose management.
- This tool supports adherence to Japan diagnostic reference levels 2020 (DRLs 2020) in clinical practice.
More Related Videos
Related Concept Videos
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Dose-Response Relationship: Overview
Radiation: Applications
The average...
Nursing Clinical Information System
A Nursing Clinical Information System (NCIS) is a specialized type of healthcare information system tailored to meet the unique needs of nursing practice. It incorporates the principles of nursing informatics to streamline information management and improve the quality of care delivery.
Critical attributes of NCIS include: