Related Experiment Video
Updated: Sep 5, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
[Detection of drugs in urine by ambient direct ionization mass spectrometry]
Shiling Xiong1, Huanhuan Hong1,2, Luhong Wen1,2
1Research Institute of Advanced Technologies, Ningbo University, Ningbo 315211, China.
Abstract:
According to the Report of Drug Situation in China (2020), the growth rate of the number of drug abusers in China has decreased, but the number of drug abusers is still large. An efficient screening method is necessary for controlling drug abuse. As an important type of biological sample, urine is widely used for the rapid screening of drug addicts. However, because of the complex composition, low content, and strong interference from the body's metabolism, the detection of drugs in urine remains a challenge. Traditional rapid screening techniques such as immunocolloidal gold analysis have a high false positive rate and insufficient quantitative capability. In addition, laboratory mass spectrometry methods require complicated time-consuming sample pre-processing and strict environmental conditions, and hence, are unsuitable for on-site rapid analysis. In recent years, various direct ionization mass spectrometry techniques such as direct analysis in real time (DART), desorption electrospray ionization (DESI), and dielectric barrier discharge ionization (DBDI) have advanced rapidly. These techniques have been applied to public safety, food safety, environmental detection, etc. In contrast to traditional ionization mass spectrometry methods, these direct ionization techniques allow for the in situ analysis of samples with simple or no pretreatment; moreover, they have the advantages of high analytical efficiency and sensitivity. In particular, pulsed electrospray ionization has the characteristics of less sample demand, compact, lightweight equipment, and no carrier gas. This paper presents a rapid method based on pulsed electrospray ionization mass spectrometry for the detection of urine samples. A rapid detection platform comprising a probe electrospray ionization source, a portable linear ion trap mass spectrometer (MS), and their coupling interface is adopted. The probe electrospray ion source includes a conducting metal wire, plastic handle, and silica glass capillary, whose tip has an inner diameter of 50 μm. The guide rail at the coupling interface is used to align the probe with the sample inlet of the portable mass spectrometer and maintain a distance of 10 mm between the probe tip and the sample inlet of the MS. The spray voltage of the probe electrospray ion source and the temperature of the MS inlet capillary are optimized at 1.8 kV and 205 ℃, respectively. In addition, rapid and efficient pretreatment techniques for urine samples have been developed. Buffer salts used for pH regulation and liquid-liquid extraction based on ethyl acetate were adopted for the pretreatment process. The linearity of the detection ability and the linear ranges of various drug-spiked solutions were also investigated. The results showed that the correlation coefficients for the quantitative detection of methamphetamine, ketamine, methylenedioxymethamphetamine (MDMA), and cocaine were greater than 0.99 at concentrations ranging from 1 to 100 ng/mL. Moreover, the limits of detection (LODs) for the five conventional drug-spiked urine were 0.5-30 ng/mL. The spiked recoveries ranged from 56.1% to 103.7%, with relative standard deviations (RSDs) of 9.0%-27.8%, implying that the combination of the instruments and the pretreatment method can lead to good accuracy. To validate the performance of the rapid detection method, 40 positive and 110 negative urine samples were tested and analyzed. The overall accuracy was over 99%, and the five conventional drugs in urine samples could be detected within 20 s. The research findings of this work could promote the development of rapid detection technology, accelerate the popularization and application of ambient direct ionization mass spectrometry, and improve the services of on-site law enforcement.
More Related Videos
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography: Types of Detectors-II
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Chemical Ionization (CI) Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...