Blood pressure measurement using only a smartphone
Related Experiment Video
Updated: Sep 5, 2025

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Lorenz Frey1, Carlo Menon1, Mohamed Elgendi2
1Biomedical and Mobile Health Technology Lab, ETH Zurich, Zurich, 8008, Switzerland.
Abstract:
Hypertension is an immense challenge in public health. As one of the most prevalent medical conditions worldwide, it is a major cause of premature death. At present, the detection, diagnosis and monitoring of hypertension are subject to several limitations. In this review, we conducted a literature search on blood pressure measurement using only a smartphone, which has the potential to overcome current limitations and thus pave the way for long-term ambulatory blood pressure monitoring on a large scale. Among the 333 articles identified, we included 25 relevant articles over the past decade (November 2011-November 2021) and analyzed the described approaches to the types of underlying data recorded with smartphone sensors, the signal processing techniques applied to construct the desired signals, the features extracted from the constructed signals, and the algorithms used to estimate blood pressure. In addition, we analyzed the validation of the proposed methods against reference blood pressure measurements. We further examined and compared the effectiveness of the proposed approaches. Among the 25 articles, 23 propose an approach that requires direct contact between the sensor and the subject and two articles propose a contactless approach based on facial videos. The sample sizes in the identified articles range from three to 3000 subjects, where 8 articles used sample sizes of 85 or more subjects. Furthermore, 10 articles include hypertensive subjects in their participant pools. The methodologies applied for the evaluation of blood pressure measurement accuracy vary considerably among the analyzed articles. There is no consistency regarding the methods for blood pressure data collection and the reference blood pressure measurement and validation. Moreover, no established protocol is currently available for the validation of blood pressure measuring technologies using only a smartphone. We conclude the review with a discussion of the results and with recommendations for future research on the topic.
Related Concept Videos
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.