Serap Çuhadar1, Hayat Özkanay-Yörük1, Mehmet Köseoğlu2
1Department of Biochemistry, Atatürk Training and Research Hospital, Izmir, Turkey.
Introduction:
Blood gas analysis (BGA) is an essential test used for years to provide vital information in critically ill patients. However, the instability of the blood gases is a problem. We aimed to evaluate time and temperature effects on blood gas stability.
Materials And Methods:
Arterial blood was collected from 20 patients into syringes. Following BGA for baseline, syringes were divided into groups to stand at 4°C and 22°C for 30, 60, 90, 120 minutes. All were tested for pH, partial pressure of carbon dioxide (pCO2), partial pressure of oxygen (pO2), oxygen saturation (sO2), oxyhemoglobin (O2Hb), sodium, potassium, glucose, lactate, oxygen tension at 50% hemoglobin saturation (p50), and bicarbonate. A subgroup analysis was performed to detect the effect of air on results during storage. Percentage deviations were calculated and compared against the preset quality specifications for allowable total error.
Results:
At 4°C, pO2 was the least stable parameter. At 22°C, pO2 remained stable for 120 min, pH and glucose for 90 min, lactate and pCO2 for 60 min. Glucose and lactate were stable when chilled. Air bubbles interfered pO2 regardless of temperatures, whereas pCO2 increased significantly at 22°C after 30 min, and pH decreased after 90 min. Bicarbonate, sO2, O2Hb, sodium, and potassium were the unaffected parameters.
Conclusions:
Correct BGA results are essential, and arterial sample is precious. Therefore, if immediate analysis cannot be performed, up to one hour, syringes stored at room temperature will give reliable results when care is taken to minimize air within the blood gas specimen.
More Related Videos
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)