Dual Plate Minifragment Fixation of Clavicle Fractures- Technique and Approach
Elizabeth Zielinski1, Keli Doe2, Paul Perdue1
1Department of Orthopaedic Surgery, Virginia Commonwealth University Health System, Richmond, VA; and.
Summary:
The treatment of midshaft clavicle fractures continues to evolve, with a variety of fixation techniques and constructs used. Symptomatic hardware is a common complication related to plate fixation of the clavicle, and often results in secondary surgery for implant removal. The minifragment dual plate fixation technique for clavicle fractures provides a construct that may result in fewer implant related complications with comparable fixation stability to precontoured locking plates. Our case presentation demonstrates our approach to midshaft clavicle fractures, the benefits of this surgical technique, and reported outcomes from this fixation method.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History: