Related Experiment Video
Updated: Sep 4, 2025

Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
A fast, single column high-performance anion exchange chromatography with pulsed amperometric detection method for
Sachin Patil1, Jeffrey Rohrer1
1Thermo Fisher Scientific, Sunnyvale, CA, 94085, USA.
Abstract:
Saccharides, especially anhydro sugars present in atmospheric aerosols, can be used as tracers to track sources of atmospheric aerosols. High-performance anion-exchange chromatography with pulsed amperometric detection is a commonly used technique for determining these saccharides, but the reported methods suffer from three drawbacks. First, to achieve separation of the complete set of atmospheric saccharides, run times are very long, typically longer than 60 minutes. Second, some methods require two columns to achieve the desired separation. Finally, in an era when electrolytic eluent preparation allows for excellent precision and accuracy, these methods require manually prepared eluents, which can lead to separation inconsistency for closely eluting analytes. These drawbacks make existing methods difficult to automate. To address this issue, we developed a fast method that uses only a single column for separation and electrolytically generated eluent that resolves 12 key atmospheric aerosol saccharides in 20 minutes. The resolved saccharides include anhydro sugars (levoglucosan, galactosan, and mannosan), sugar alcohols (erythritol, xylitol, and mannitol), and mono-/disaccharides (arabinose, galactose, glucose, mannose, fructose, and sucrose). To our knowledge, this report is the first instance of achieving such a significant reduction in run time with good resolution for this set of saccharides.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Detectors-II
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...