Related Experiment Video
Updated: Sep 4, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Comparison of Changes in Thoracic Fluid Content Between On-Pump and Off-Pump CABG by Use of Electrical Cardiometry
Surendra Kumar Jangid1, Neeti Makhija1, Sandeep Chauhan1
1Department of Cardiac Anaesthesia & Critical Care, Cardiothoracic Centre, CNC, All India Institute of Medical Sciences, Ansari Nagar, New Delhi, India.
Objectives:
To compare the changes in thoracic fluid content, PaO2/FIO2 ratio, plateau pressure, compliance, and postoperative ventilation duration in off-pump coronary artery bypass grafting (OPCAB) and on-pump coronary artery bypass grafting (ONCAB).
Design:
Prospective observational study.
Setting:
Tertiary-care cardiac center.
Participants:
Over an 18-month period, from December 2019 to May 2021, 111 patients who underwent CAB grafting were enrolled. Group I constituted OPCAB patients and Group II the ONCAB patients.
Interventions:
After induction, the authors measured thoracic fluid content (TFC), pulmonary compliance, airway pressures, and the PaO2/FIO2 ratio before skin incision (T1) and after skin closure (T2). The input, output, as well as the duration of postoperative ventilation, also were recorded.
Results:
At T2, the ONCAB group had a significantly higher change in TFC than the OPCAB group (5.4 ± 1.86 kOhm-1v 4.32 ± 1.84 kOhm-1, p = 0.012). The fluid balance was significantly higher in the OPCAB group compared with the ONCAB group (2,159.21 ± 108.73 mL v 1,792.50 ± 151.88 mL, p = 0.0001). The decrease in PaO2/FIO2 ratio was significantly lower in the OPCAB group compared with the ONCAB group (-71.34 ± 23.42 v -123.65 ± 36.81, p = 0.000). The increase in plateau pressure, decrease in compliance, and postoperative ventilation period were significantly higher in the patients who underwent ONCAB than the patients who underwent OPCAB (p < 0.05).
Conclusion:
The change in TFC was greater in the ONCAB group, despite the fact that the fluid balance was higher in the OPCAB group. A higher TFC in ONCAB led to lower PaO2/FIO2 ratio, lower compliance, higher plateau pressures, and longer postoperative ventilation.
More Related Videos
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...

