Related Experiment Video
Updated: Sep 4, 2025

Fluorescent Paper Strips for the Detection of Diesel Adulteration with Smartphone Read-out
Published on: November 9, 2018
Smartphone as a Portable Detector for Thin-Layer Chromatographic Determination of Some Gastrointestinal Tract Drugs
Maha Mahmoud Ibrahim1, Khadiga Mohamed Kelani1,2, Nesreen Khamis Ramadan2
1Analytical Chemistry Department, Faculty of Pharmacy, Modern University for Technology and Information, 12055 Cairo, Egypt.
Abstract:
Thin-layer chromatography (TLC) is an effective and simple technique for screening, evaluating, and quantifying low-quality and counterfeit pharmaceutical products. Smartphones have recently been used as accessible, cheap, and portable detectors that can replace more complicated analytical detectors. In this work, we have developed a simple and sensitive TLC method utilizing a smartphone charged-coupled device (CCD) camera not only to verify and quantify some gastrointestinal tract drugs, namely, loperamide hydrochloride (LOP) and bisacodyl (BIS), but also to detect acetaminophen (ACT) as a counterfeit drug. Both drugs (LOP and BIS) were chromatographed separately on a silica gel 60 F254 plate as a stationary phase under previously reported chromatographic conditions, using ethyl acetate:methanol:ammonium hydroxide (24:3:1, by volume) and ethyl acetate:methanol:glacial acetic acid (85:10:5, by volume) as developing systems to determine LOP and BIS, respectively. Universal stains, namely, iodine vapors and vanillin, were used to visualize the spots on the TLC plates to get a visual image using the smartphone camera and a spotlight as an illumination source with no need for a UV illumination source. The spot intensity was calculated using a commercially available smartphone application for quantitative analysis of the studied drugs utilizing ″acetaminophen″ as an example of a counterfeit substance. Rf values were calculated using the recorded images and found to be 0.77, 0.79, and 0.74 for LOP, BIS, and ACT, respectively, providing drug identity. Linear calibration curves using the smartphone-TLC method were obtained between the luminance and the corresponding concentrations over the ranges of 2.00-10.00 μg/mL and 1.00-10.00 μg/mL with limits of detection of 0.57 and 0.10 μg/mL for LOP and BIS, respectively. The suggested method was validated according to the International Conference of Harmonization (ICH) guidelines. The method was then successfully applied for the qualitative and quantitative determination of LOP or BIS as an example for gastrointestinal tract drugs in pure form and in their pharmaceutical dosage formulations. The proposed method is considered as a perfect alternative to traditional reported densitometric methods due to its simplicity, easy application, and inexpensiveness. No previously reported methods utilizing smartphones have been published for the determination of the studied drugs. The developed approach is considered the first TLC method using smartphones for the determination of some gastrointestinal tract drugs in their pure form and in pharmaceutical formulations.
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...