Ozone treatment effectively eliminates SARS-CoV-2 from infected face masks

Elizabeth Córdoba-Lanús1,2,3,4, Omar García-Pérez1,2,3, Francisco Rodríguez-Esparragón4,5,6

  • 1Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias de la Universidad de La Laguna, La Laguna, Tenerife, Spain.

Plos One
|July 22, 2022
PubMed

Related Concept Videos

Administering Oxygen by Mask01:30

Administering Oxygen by Mask

Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
710
Oxidative Cleavage of Alkenes: Ozonolysis01:46

Oxidative Cleavage of Alkenes: Ozonolysis

In ozonolysis, ozone is used to cleave a carbon–carbon double bond to form aldehydes and ketones, or carboxylic acids, depending on the work-up.
Ozone is a symmetrical bent molecule stabilized by a resonance structure.
10.9K
Oxygen Delivering System I: Nasal Cannula and Face Mask01:26

Oxygen Delivering System I: Nasal Cannula and Face Mask

The human body requires oxygen to function, and when the natural process of respiration is hindered, external devices, including the following, are needed to help deliver this vital gas.
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
562
Methods of Sterilization II: Chemical Methods01:30

Methods of Sterilization II: Chemical Methods

In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
6.8K
Physical Methods for Controlling Microbial Growth: Radiation and Filtration01:26

Physical Methods for Controlling Microbial Growth: Radiation and Filtration

Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
212
PPE Use in Healthcare Settings II: Doffing01:10

PPE Use in Healthcare Settings II: Doffing

The sequence of removing or doffing PPE starts with the gloves, as they are the most contaminated. Next is removal of the face shield or goggles, as they would interfere with removing other PPE. Then remove the gown, followed by the mask or respirator. Perform hand hygiene between steps if hands become contaminated and immediately after removing all PPE. Generally, the outside front and sleeves of the isolation gown, the goggles or the mask, the respirator, and the face shield are contaminated.