Related Experiment Video
Updated: Sep 3, 2025

Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
SPR-based assay kit for rapid determination of Pb2
Amirmostafa Amirjani1, Paria Kamani1, Hamid Reza Madaah Hosseini1
1Department of Materials Science and Engineering, Sharif University of Technology, P.O.Box: 11155-9466, Tehran, Iran.
Abstract:
A recyclable optical nanosensor was developed by immobilizing l-tyrosine functionalized silver nanoparticles (AgNPs) on the polyethylene terephthalate (PET) substrate for rapid determination of Pb2+ ions. At first, the l-tyrosine functionalized AgNPs were assessed in the solution phase; the response time was lower than 15 s, and a limit of detection lower than 9 nM was obtained in the dynamic range of 1-1000 nM. For fabrication of the optical assay kit, the design of experiment (DOE) was used to optimize the immobilization efficiency of the nanoparticles on PET films by studying AgNO3 concentration and pH as two crucial parameters. The assay kit in optimal conditions showed a sharp localized surface plasmon resonance band suitable for sensitive determination of Pb2+. The fabricated sensor showed promising results for rapid determination of lead ions with the limit of detection value as low as 1 nM (S/N = 3). The sensor reproduced the obtained results even after three consecutive runs, which proved the recyclability of the optical assay kit. The recoveries of the spiked concentration in real samples were in the range of 95%-103%, which confirmed the applicability of the sensor in practical applications.