Cardiac computed tomography using redundant-ray prospective gating.

S C Moore, P F Judy

    Medical Physics
    |March 1, 1987
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Determining the effect of cardiac blood volume on accuracy of uptake rate constants by simulation.

    Physics in medicine and biology·2023
    Same author

    Metabolomics and cancer preventive behaviors in the BC Generations Project.

    Scientific reports·2021
    Same author

    Electronic Longitudinal Alcohol Study in Communities (ELAStiC) Wales - protocol for platform development.

    International journal of population data science·2021
    Same author

    Development and feasibility of quantitative dynamic cardiac imaging for mice using μSPECT.

    Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology·2020
    Same author

    Telephone review after minor oral surgery.

    The British journal of oral & maxillofacial surgery·2016
    Same author

    Effect of pinhole shape on projection resolution.

    Physics in medicine and biology·2016
    Same journal

    Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

    Medical physics·2026
    Same journal

    Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

    Medical physics·2026
    Same journal

    Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

    Medical physics·2026
    Same journal

    Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

    Medical physics·2026
    Same journal

    Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

    Medical physics·2026
    Same journal

    Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

    Medical physics·2026
    See all related articles

    This study introduces redundant-ray prospective gating for cardiac CT imaging. This novel method improves scan efficiency and temporal resolution, enabling clearer visualization of the cardiac cycle.

    Area of Science:

    • Medical Imaging
    • Radiologic Technology
    • Cardiovascular Imaging

    Background:

    • Conventional prospective gating in cardiac computed tomography (CT) involves ECG monitoring to initiate scans.
    • Each scan acquires redundant projection data due to reversed source-detector positions.
    • This redundancy presents an opportunity for improved data acquisition efficiency.

    Purpose of the Study:

    • To modify a fourth-generation CT scanner for cardiac imaging.
    • To implement a novel redundant-ray prospective gating technique.
    • To enhance scan efficiency and temporal resolution in cardiac CT.

    Main Methods:

    • Modified a CT scanner for prospectively gated cardiac imaging.
    • Developed a redundant-ray prospective gating algorithm utilizing sinogram data.

    Related Experiment Videos

  • Acquired cardiac images using a heart phantom at 90 beats per minute.
  • Main Results:

    • Achieved 100-ms temporal resolution across all cardiac phases in four scans using redundant-ray gating.
    • Conventional prospective gating in four scans resulted in lower image quality and 170-ms resolution.
    • Demonstrated improved efficiency and temporal resolution with the new gating method.

    Conclusions:

    • Redundant-ray prospective gating significantly enhances cardiac CT imaging efficiency.
    • This technique allows for superior temporal resolution, crucial for dynamic cardiac assessments.
    • The method offers a promising advancement for cardiac CT data acquisition.