Related Experiment Video
Updated: Sep 3, 2025

Lens-free Video Microscopy for the Dynamic and Quantitative Analysis of Adherent Cell Culture
Published on: February 23, 2018
Noise-robust phase-space deconvolution for light-field microscopy
Tianyi Zhu1, Yuduo Guo1, Yi Zhang2
1Tsinghua University, Tsinghua-Berkeley Shenzhen Institute, Beijing, China, China.
Significance:
Light-field microscopy has achieved success in various applications of life sciences that require high-speed volumetric imaging. However, existing light-field reconstruction algorithms degrade severely in low-light conditions, and the deconvolution process is time-consuming.
Aim:
This study aims to develop a noise robustness phase-space deconvolution method with low computational costs.
Approach:
We reformulate the light-field phase-space deconvolution model into the Fourier domain with random-subset ordering and total-variation (TV) regularization. Additionally, we build a time-division-based multicolor light-field microscopy and conduct the three-dimensional (3D) imaging of the heart beating in zebrafish larva at over 95 Hz with a low light dose.
Results:
We demonstrate that this approach reduces computational resources, brings a tenfold speedup, and achieves a tenfold improvement for the noise robustness in terms of SSIM over the state-of-the-art approach.
Conclusions:
We proposed a phase-space deconvolution algorithm for 3D reconstructions in fluorescence imaging. Compared with the state-of-the-art method, we show significant improvement in both computational effectiveness and noise robustness; we further demonstrated practical application on zebrafish larva with low exposure and low light dose.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Super-resolution Fluorescence Microscopy
Confocal Fluorescence Microscopy
Light Acquisition
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

