Related Experiment Video
Updated: Sep 3, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Calculation of Aortic VAlve and LVOT Areas by a Modified Continuity Equation Using Different Echocardiography
Tobias Friedrich Ruf1, Béatrice Elise Cannard2, Ruth H Strasser3
1Center for Cardiology, Cardiology I, University Medical Center Mainz, 55131 Mainz, Germany.
Background:
The area of the left ventricular outflow tract (ALVOT) represents a major component of the continuity equation (CE), which is, i.a., crucial to calculate the aortic valve (AV) area (AAV). The ALVOT is typically calculated using 2D echo assessments as the measured anterior-posterior (a/p) extension, assuming a round LVOT base. Anatomically, however, usually an elliptical shape of the LVOT base is present, with the long diameter extending from the medial-lateral axis (m/l), which is not recognized by two-dimensional (2D) echocardiography.
Objective:
We aimed to compare standard and three-dimensional (3D)-echocardiography-derived ALVOT calculation and its use in a standard CE (CEstd) and a modified CE (CEmod) to calculate the AAV vs. computed tomography (CT) multi-planar reconstruction (MPR) measurements of the anatomical ALVOT, and AAV, respectively.
Methods:
Patients were selected if 3D transthoracic echocardiography (TTE), 3D transesophageal echocardiography (TEE), and cardiac CT were all performed, and imaging quality was adequate. The ALVOT was assessed using 2D calculation, (a/p only), 3D-volume MPR, and 3D-biplane calculation (a/p and m/l). AAV was measured using both CEstd and CEmod, and 3D-volume MPR. Data were compared to corresponding CT analyses.
Results:
From 2017 to 2018, 107 consecutive patients with complete and adequate imaging data were included. The calculated ALVOT was smaller when assessed by 2D- compared to both 3D-volume MPR and 3D-biplane calculation. Calculated AAV was correspondingly smaller in CEstd compared to CEmod or 3D-volume MPR. The ALVOT and AAV, using data from 3D echocardiography, highly correlated and were congruent with corresponding measurements in CT.
Conclusion:
Due to the elliptic shape of the LVOT, use of measurements and calculations based on 2D echocardiography systematically underestimates the ALVOT and dependent areas, such as the AAV. Anatomically correct assessment can be achieved using 3D echocardiography and adapted calculations, such as CEmod.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...