Related Experiment Video
Updated: Sep 3, 2025

MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
Published on: January 16, 2021
Optimization Design of Magnetic Isolation Ring Position in AC Solenoid Valves for Dynamic Response Performances
Jiang Guo1,2, Linguang Li1, Pu Qin1
1Key Laboratory for Precision and Non-Traditional Machining Technology of Ministry of Education, Dalian University of Technology, Dalian 116024, China.
Abstract:
Dynamic response characteristics of solenoid valves directly determined their performances. Among numerous parameters, the influence of magnetic isolation ring (MIR) on solenoid valve performance is crucial. Previous optimization studies have not conducted a systematic exploration and analysis of MIR. In this paper, a model of an AC solenoid valve considering the position of the MIR is proposed, and the model's accuracy was verified by simulation and experiments. The electromagnetic force, response time, and magnetic field distribution at different positions of the MIR were analyzed, and the effect of the position of MIR on dynamic response characteristics of the solenoid valve was clarified. The results show that the MIR affects the dynamic response characteristics of the solenoid valve by changing the magnetic circuit. With the positive translation of the position of the MIR along the Z-axis, the electromagnetic force first increases and then decreases, and the response time first decreases and then increases. The position range of MIR with excellent dynamic response performance was obtained from the comprehensive consideration of response time and electromagnetic force. Finally, the optimization design for the dynamic response performance of the solenoid valves is realized.
Related Concept Videos
Magnetic Field of a Solenoid
Consider a solenoid with 100 turns wrapped around a cylinder of...
Solenoids
Each turn in a solenoid can be approximated as a circular current carrying coil that generates a dipole moment. The...
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Magnetic Field Of A Current Loop
Force On A Current Loop In A Magnetic Field