Related Experiment Video
Updated: Sep 3, 2025

O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
Computational fluid dynamics investigation on aortic hemodynamics in double aortic arch before and after ligation
Yunfei Ling1, Torsten Schenkel2, Jiguo Tang3
1Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu 610041, China; State Key Laboratory of Hydraulics and Mountain River Engineering, College of Water Resource & Hydropower, Sichuan University, Chengdu 610065, China.
Abstract:
Double aortic arch (DAA) malformation is one of the reasons for symptomatic vascular rings, the hemodynamics of which is still poorly understood. This study aims to investigate the blood flow characteristics in patient-specific double aortic arches using computational fluid dynamics (CFD). Seven cases of infantile patients with DAA were collected and their computed tomography images were used to reconstruct 3D computational models. A modified Carreau model was used to consider the non-Newtonian effect of blood and a three-element Windkessel model taking the effect of the age of patients into account was applied to reproduce physiological pressure waveforms. Numerical results show that blood flow distribution and energy loss of DAA depends on relative sizes of the two aortic arches and their angles with the ascending aorta. Ligation of either aortic arch increases the energy loss of blood in the DAA, leading to the increase in cardiac workload. Generally, the rising rate of energy loss before and after the surgery is almost linear with the area ratio between the aortic arch without ligation and the ascending aorta.