Related Experiment Video
Updated: Sep 3, 2025

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Multiparametric cloth-based wearable, SimpleSense, estimates blood pressure
Prashanth Shyam Kumar1, Pratyush Rai2, Mouli Ramasamy2
1Nanowear Inc., Brooklyn, NY, USA. prashanth@nanowearinc.com.
Abstract:
Targeted maintenance of blood pressure for hypertensive patients requires accurate monitoring of blood pressure at home. Use of multiparametric vital signs ECG, heart sounds, and thoracic impedance for blood pressure estimation at home has not been reported previously. In an observational multi-site study, 120 subjects (female (N = 61, 52%)) between 18 and 83 years of age were recruited with the following stratification (Normal (20%), prehypertensive (37%), stage 1(26%), and stage 2 (18%). From these subjects, 1686 measurements of blood pressure from a sphygmomanometer were associated with simultaneously acquired signals from the SimpleSense device. An ensemble of tree-based models was trained with inputs as metrics derived from the multiparametric and patient demographics data. A test Mean Absolute Difference (MAD) of ± 6.38 mm of Hg and ± 5.10 mm of Hg were obtained for systolic and diastolic blood pressures (SBP; DBP), respectively. Comparatively, the MAD for wrist-worn blood pressure cuff OMRON BP6350 (GUDID-10073796266353) was ± 8.92 mm of Hg and ± 6.86 mm of Hg, respectively. Machine learning models trained to use multiparametric data can monitor SBP and DBP without the need for calibration, and with accuracy levels comparable to at-home cuff-based blood pressure monitors.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: