Comparison of two coracoid process transfer techniques on stress shielding using three-dimensional finite-element
Seyyid Serif Unsal1, Tugrul Yildirim2, Murat Kayalar3
1Trabzon Kanuni Research and Education Hospital, Trabzon, Turkey.
The congruent-arc Latarjet (CAL) technique may cause more graft osteolysis than the traditional Latarjet (TL) technique. CAL models showed less stress on the proximal graft, potentially hindering bone formation and increasing graft resorption.
Area of Science:
- Orthopedic surgery
- Biomechanical engineering
- Computational modeling
Background:
- Shoulder instability often requires surgical intervention.
- The Latarjet procedure is a common surgical treatment for anterior shoulder instability.
- Variations in the Latarjet technique exist, including traditional (TL) and congruent-arc (CAL) methods.
Purpose of the Study:
- To compare the stress distribution patterns of the CAL and TL Latarjet procedures using patient-specific 3D finite-element models.
- To evaluate the influence of glenoid defects and arm positions on stress distribution in both Latarjet techniques.
Main Methods:
- Developed 3D finite-element models of the glenohumeral joint from CT data of 10 patients.
- Simulated TL and CAL Latarjet procedures with 25% and 35% glenoid bone defects.
- Applied simulated joint loading and analyzed von Mises stress distribution on the coracoid graft.
Main Results:
- The traditional Latarjet (TL) technique exhibited significantly greater mean von Mises stress on the graft compared to the congruent-arc Latarjet (CAL) technique.
- TL models showed higher stress in the distal medial graft, while CAL models had stress concentrated on the distal lateral edge.
- Increasing glenoid defect size significantly increased lateral graft stress in both techniques.
Conclusions:
- Stress distribution patterns and magnitudes differ significantly between CAL and TL Latarjet techniques.
- The CAL technique's lower stress on the proximal-medial graft may impede bone formation, potentially leading to increased graft osteolysis.
- The CAL technique might be associated with a higher incidence of graft osteolysis compared to the TL technique.
Related Concept Videos
Shearing Stress
The average shearing stress can be calculated by dividing the shear by the area of the cross-section.
Transformation of Plane Stress
Stress Concentrations in Circular Shafts
Bearing Stress
Due to the intricacy of these microforces, an average value, known as bearing stress, is often used by...
Stress on an Oblique Plane
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...