Kinetics and mechanism of ozonation to treat Microcystis-laden source waters affected by cell-viability
Xi Li1, Weijun Song2, Sheng Chen3
1CAS Key Laboratory of Urban Pollutant Conversion, Institute of Urban Environment, Chinese Academy of Sciences, Xiamen 361021, China.
Abstract:
Toxic cyanobacteria are challenging drinking water safety globally, and their cell-viability declines at decay stage of a succussive bloom. Ozone might be a more effective oxidant to treat both high- and low-viability cyanobacteria than other common oxidants (e.g., chlorine, potassium permanganate). However, previous studies only conducted ozonation experiments using high-viability cyanobacteria, and potential influences of cell-viability on ozonation process, remains unknown. In this study, kinetics of ozone decay, cell inactivation, membrane destruction, and cyanotoxin fate of high- and low-viability Microcystis (the most common genus), was investigated, and associated mechanism was discussed. Results showed that low-viability Microcystis exhibited a higher rate constant of membrane destruction (665-744 M-1 s-1) than high-viability Microcystis (364-600 M-1 s-1) by equal concentrations of ozone, ascribed to loosely gelatinous sheath comprised with fewer organic matters as oxidant scavengers. Meanwhile, a higher rate constant of photosynthetic inactivation induced by ozonation, was observed for low-viability Microcystis (312-364 M-1 s-1) than that for high-viability Microcystis (168-294 M-1 s-1). However, elevated aromatic organics competitively inhibited microcystin ozonation for low-viability Microcystis, and hydroxyl radicals for microcystin oxidation could be reduced by elevated organic loads and alkalinity. Moreover, elevated ozone exposure (>51 mg min L-1) did not totally oxidize microcystin with a residual of 30 μg L-1 for low-viability Microcystis. These findings suggested that elevated microcystin risk would be the great barrier to limit ozonation application for low-viability Microcystis, even with benefits of higher cell inactivation compared to high-viability Microcystis.
More Related Videos
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
Oxidative Cleavage of Alkenes: Ozonolysis
Ozone is a symmetrical bent molecule stabilized by a resonance structure.
Oxygen Requirements and Growth Patterns
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Chemical Agents for Microbial Control
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Antimicrobial Effectiveness