Cardiac Strangulation in Children: Asymptomatic Complication of Epicardial Pacing
Olga Yu Dzhaffarova1, Liliya I Svintsova1, Elena O Kartofeleva1
1Cardiology Research Institute, Tomsk National Research Medical Center, Russian Academy of Sciences, Tomsk, Russia.
Insights
Cardiac strangulation, a rare complication of epicardial pacemaker implantation, can be life-threatening in children. This report details two cases of left ventricular strangulation in young children, highlighting this serious risk.
Area of Science:
- Pediatric Cardiology
- Cardiovascular Surgery
- Biomedical Engineering
Background:
- Epicardial pacemaker implantation is a common procedure in pediatric patients requiring long-term pacing.
- Mechanical complications, though infrequent, can arise from implanted devices, particularly in growing children.
- Cardiac strangulation represents a severe, albeit rare, adverse event associated with these systems.
Observation:
- Two pediatric cases of left ventricular strangulation following early-age epicardial pacemaker implantation are presented.
- The patients, aged 4 and 3 years, developed this mechanical complication.
- The strangulation involved the left ventricle, indicating a significant impact on cardiac function.
Findings:
- The findings underscore the potential for cardiac strangulation as a serious complication of pediatric epicardial pacemaker systems.
- Early implantation in growing children appears to be a risk factor.
- Prompt recognition and management are crucial for patient outcomes.
Implications:
- This case series highlights the need for vigilance regarding mechanical complications in pediatric patients with epicardial pacemakers.
- Further research into device design and implantation techniques may be warranted to mitigate risks.
- Clinicians should consider cardiac strangulation in the differential diagnosis of unexplained symptoms in children with these devices.
Abstract:
Cardiac strangulation is a rare but potentially life-threatening mechanical complication associated with epicardial pacemaker implantation in growing children. This article presents 2 case reports of left ventricular strangulation in 4- and 3-year-old children who had an epicardial pacemaker system implanted at an early age. (Level of Difficulty: Advanced.).
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022
Related Concept Videos
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Pericarditis II: Clinical Features and Diagnostic Tests
Cardiac Catheterization II: Right Heart Catheterization
Mechanism of Cardiac Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Rheumatic Heart Disease I: Introduction