Objectives:
In this cadaveric study, the accuracy of CAS guided mandibular and maxillary reconstruction including immediate dental implant placement in different Brown defect classes is assessed.
Materials And Methods:
The virtual planning and surgical procedure was conducted according to a newly proposed Amsterdam UMC reconstruction protocol. Postoperative evaluation was performed according to a previously proposed evaluation guideline.
Results:
Fourteen mandibular and 6 maxillary reconstructions were performed. Average mandibular angle deviations were 1.52°±1.32, 1.85°±1.58, 1.37°±1.09, 1.78°±1.37, 2.43°±1.52 and 2.83°±2.37, respectively for the left and right axial angles, left and right coronal angles and left and right sagittal angles. A total of 62 dental implants were placed in neomandibles with an average dXYZ values of 3.68 ± 2.21 mm and 16 in neomaxillas with an average dXYZ values of 3.24 ± 1.7 mm.
Conclusion:
Promising levels of accuracy were achieved for all mandibular angles. Dental implant positions approached the preoperative preferred positions well, within the margin to manufacture prosthetic devices.