Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Modeling of the first dimensional peak with two modulated sub-peaks in comprehensive two-dimensional gas
1School of Information Engineering, Wuhan Business University, #816 Dongfeng Avenue, Wuhan, Hubei, 430010, People's Republic of China.
Abstract:
According to previous published works, precise modeling of the first dimensional (1D) peak in comprehensive two-dimensional gas chromatography (GC × GC) requires at least 3 modulated sub-peaks (MSP). This requirement is sometimes difficult to meet, e.g., in case of undersampling modulation. In the present work, the feasibility of modeling of the 1D peak with only 2 MSP was demonstrated. The effects of modulation phase (ϕ), modulation period (PM), the peak width (1σ), and the peak shape of the original 1D peak on the accuracy of the proposed method were explored. When employing PM ranging from 6 s ~ 3 s to modulate original peaks with 1σ = 1.2 s ~ 0.6 s, the maximal error of the modeled 1tR is 1.08 s, which is far less than the error generated by employing the largest MSP to estimate the 1tR. The deviation of modeled 1tR increases with the increase of peak shape distortion, and this deviation is ≤ 0.67 s when tailing factor (Tf) in the range of 0.8 to 1.5. The application of the proposed method was demonstrated by assisting identification of a monoterpene in Myrrh sample. The proposed approach could improve the accuracy in calculation of 1tR or 1I and enhance the reliability of compound identification in GC × GC analysis with undersampling modulation.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...