Related Experiment Video
Updated: Sep 2, 2025

Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies
Published on: December 15, 2023
Artificial intelligence using deep neural network learning for automatic location of the interscalene brachial plexus
Xiao-Yu Yang1, Le-Tian Wang, Gen-Di Li
1From the Department of Anaesthesiology, Huashan Hospital Fudan University (X-YY, L-TW, D-LL, Q-LG, Q-RZ, TG, H-LW, Y-WW), Department of Surgery Nursing, Huashan Hospital Fudan University (G-DL) and the Academy for Engineering and Technology, Fudan University, Shanghai, China (Z-KY).
Background:
Identifying the interscalene brachial plexus can be challenging during ultrasound-guided interscalene block.
Objective:
We hypothesised that an algorithm based on deep learning could locate the interscalene brachial plexus in ultrasound images better than a nonexpert anaesthesiologist, thus possessing the potential to aid anaesthesiologists.
Design:
Observational study.
Setting:
A tertiary hospital in Shanghai, China.
Patients:
Patients undergoing elective surgery.
Interventions:
Ultrasound images at the interscalene level were collected from patients. Two independent image datasets were prepared to train and evaluate the deep learning model. Three senior anaesthesiologists who were experts in regional anaesthesia annotated the images. A deep convolutional neural network was developed, trained and optimised to locate the interscalene brachial plexus in the ultrasound images. Expert annotations on the datasets were regarded as an accurate baseline (ground truth). The test dataset was also annotated by five nonexpert anaesthesiologists.
Main Outcome Measures:
The primary outcome of the research was the distance between the lateral midpoints of the nerve sheath contours of the model predictions and ground truth.
Results:
The data set was obtained from 1126 patients. The training dataset comprised 11 392 images from 1076 patients. The test dataset constituted 100 images from 50 patients. In the test dataset, the median [IQR] distance between the lateral midpoints of the nerve sheath contours of the model predictions and ground truth was 0.8 [0.4 to 2.9] mm: this was significantly shorter than that between nonexpert predictions and ground truth (3.4 mm [2.1 to 4.5] mm; P < 0.001).
Conclusion:
The proposed model was able to locate the interscalene brachial plexus in ultrasound images more accurately than nonexperts.
Trial Registration:
ClinicalTrials.gov (https://clinicaltrials.gov) identifier: NCT04183972.
More Related Videos
04:23A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
Related Concept Videos
Spinal Nerves: Plexus I
The Cervical Plexus
The cervical plexus, formed by the anterior rami of the first four...
Ultrasonography
During an ultrasonography procedure, a handheld device called...