Related Experiment Video
Updated: Sep 2, 2025

Preparation and Application of a New Bacterial Biosensor for the Presumptive Detection of Gunshot Residue
Published on: May 9, 2019
Fast and Selective Detection of Trace Chemical Warfare Agents Enabled by an ESIPT-Based Fluorescent Film Sensor
Ke Liu1, Molin Qin2, Qiyuan Shi1
1Key Laboratory of Applied Surface and Colloid Chemistry of Ministry of Education, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, P. R. China.
Abstract:
Reliable detection of airborne chemical warfare agents (CWAs) at the site and in real-time remains a challenge due to the rarity of miniaturized analytical tools. Herein, an o-carborane-functionalized benzothiazole derivative (PCBO) with excited-state intramolecular proton transfer (ESIPT) and AIE characteristics was synthesized. The PCBO-based film sensor showed a highly sensitive response to representative simulants of CWAs, and detection limits were found to be 1.0 mg·m-3 for triphosgene, 6.0 mg·m-3 for chloroethyl ethyl sulfide, and 0.2 mg·m-3 for diethyl chlorophosphite. Moreover, the sensor showed great reusability (>100 cycles) and unprecedented response speed (<0.5 s). The excellent sensing performance was ascribed to the microenvironmental sensitivity of the sensing fluorophore, the porous adlayer structure of the film, and the specific binding of the fluorophore to the analytes. Furthermore, discrimination and identification of the examined CWA simulants were realized via the introduction of another fluorophore (HCBO)-based film. Importantly, a portable fluorescent CWA detector was built with the sensor as the key component, and its applicability was demonstrated by the successful detection of a typical CWA sample (Sarin). The present study indicates that fluorescent film sensors could satisfy reliable onsite and real-time detection of harmful chemicals.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
03:33Author Spotlight: Development and Application of SERS Flexible Substrates Using Synthesized AgNPs
Published on: November 17, 2023
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Atomic Fluorescence Spectroscopy
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Interference