Related Experiment Video
Updated: Sep 2, 2025

Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
Wavelet and Spectral Analysis of Normal and Abnormal Heart Sound for Diagnosing Cardiac Disorders
Amzad Hossain1, Sharif Uddin2, Parinda Rahman1
1Department of Electrical and Computer Engineering, North South University, Dhaka, Bangladesh.
Abstract:
Body auscultation is a frequent clinical diagnostic procedure used to diagnose heart problems. The key advantage of this clinical method is that it provides a cheap and effective solution that enables medical professionals to interpret heart sounds for the diagnosis of cardiac diseases. Signal processing can quantify the distribution of amplitude and frequency content for diagnostic purposes. In this experiment, the use of signal processing and wavelet analysis in screening cardiac disorders provided enough evidence to distinguish between the heart sounds of a healthy and unhealthy heart. Real-time data was collected using an IoT device, and the noise was reduced using the REES52 sensor. It was found that mean frequency is sufficiently discriminatory to distinguish between a healthy and unhealthy heart, according to features derived from signal amplitude distribution in the time and frequency domain analysis. The results of the present study indicate the adequate discrimination between the characteristics of heart sounds for automatic detection of cardiac problems by signal processing from normal and abnormal heart sounds.
Related Concept Videos
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...