Dual Energy Computed Tomography Collagen Material Decomposition for Detection of Lumbar Spine Disc Extrusion and
Waleed Abdellatif1, James P Nugent2, Faisal Alballa3
1Department of Radiology, 12334UT Southwestern Medical Center, Dallas, TX, USA.
Abstract:
Purpose: To assess value of dual energy computed tomography (DECT) collagen material decomposition algorithm when combined with standard computed tomography (CT) in detection of lumbar disc extrusion and sequestration. Materials and Methods: Retrospective analysis of all patients with acute low back pain who had a diagnosis of lumbar spine disc extrusion and/or sequestration on Magnetic Resonance Imaging (MRI) (reference standard), and had undergone non-contrast DECT of the lumbar spine within 60 days of the MRI. Age and sex-matched control patients (n = 42) were included. Patients were grouped into standard, grey-scale CT only group and standard CT + DECT tendon images group. Two double-blinded radiologists reviewed both groups for presence of extrusion or sequestration. They also rated their diagnostic confidence on Likert 5-point scale. McNemar Chi-square test was used to compare diagnostic accuracy, unpaired t-test to compare reviewers diagnostic confidence, and Cohen's k (kappa) test for interobserver agreement. Results: The combined group showed higher overall sensitivity (96.6% vs 87.2%), specificity (99% vs 95.4%), and diagnostic accuracy (98.7% vs 94.5%) with a lower false positive rate (1.1% vs 4.6%). McNemar Chi-square test confirmed statistical significance (P = .03 and P = .02 for Reviewers R1 and R2, respectively). The mean diagnostic confidence was also significantly higher on combined group (R1: 3.74 ± 1.1 vs 3.47 ± 1.15 (P < .01) and R2: 3.91 ± 1.15 vs 3.72 ± 1.16 [mean ± SD] (P = .02)). Conclusion: Utilizing MRI as a reference standard, DECT tendon application combined with standard CT increases the sensitivity, specificity, and accuracy of detection of lumbar spine disc extrusion and sequestration, when compared to standard CT alone.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography