Related Experiment Video For Breast diseases
Updated: Sep 2, 2025

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Value of magnetic resonance diffusion combined with perfusion imaging techniques for diagnosing potentially malignant
Hui Zhang1, Xin-Yi Zhang2, Yong Wang3
1Department of Radiology, Hebei General Hospital, Shijiazhuang 050000, Hebei Province, China.
Background:
Lesions of breast imaging reporting and data system (BI-RADS) 4 at mammography vary from benign to malignant, leading to difficulties for clinicians to distinguish between them. The specificity of magnetic resonance imaging (MRI) in detecting breast is relatively low, leading to many false-positive results and high rates of re-examination or biopsy. Diffusion-weighted imaging (DWI), combined with perfusion-weighted imaging (PWI), might help to distinguish between benign and malignant BI-RADS 4 breast lesions at mammography.
Aim:
To evaluate the value of DWI and PWI in diagnosing BI-RADS 4 breast lesions.
Methods:
This is a retrospective study which included patients who underwent breast MRI between May 2017 and May 2019 in the hospital. The lesions were divided into benign and malignant groups according to the classification of histopathological results. The diagnostic efficacy of DWI and PWI were analyzed respectively and combinedly. The 95 lesions were divided according to histopathological diagnosis, with 46 benign and 49 malignant. The main statistical methods used included the Student t-test, the Mann-Whitney U-test, the chi-square test or Fisher's exact test.
Results:
The mean apparent diffusion coefficient (ADC) values in the parenchyma and lesion area of the normal mammary gland were 1.82 ± 0.22 × 10-3 mm2/s and 1.24 ± 0.16 × 10-3 mm2/s, respectively (P = 0.021). The mean ADC value of the malignant group was 1.09 ± 0.23 × 10-3 mm2/s, which was lower than that of the benign group (1.42 ± 0.68 × 10-3 mm2/s) (P = 0.016). The volume transfer constant (Ktrans) and rate constant (Kep) values were higher in malignant lesions than in benign ones (all P < 0.001), but there were no significant statistical differences regarding volume fraction (Ve) (P = 0.866). The sensitivity and specificity of PWI combined with DWI (91.7% and 89.3%, respectively) were higher than that of PWI or DWI alone. The accuracy of PWI combined with DWI in predicting pathological results was significantly higher than that predicted by PWI or DWI alone.
Conclusion:
DWI, combined with PWI, might possibly distinguish between benign and malignant BI-RADS 4 breast lesions at mammography.
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI