Kinetics of capillary refill time after fluid challenge
Related Experiment Video
Updated: Sep 1, 2025

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Lisa Raia1, Paul Gabarre1,2, Vincent Bonny1,2
1Service de Médecine Intensive-Réanimation, Assistance Publique-Hôpitaux de Paris, Hôpital Saint-Antoine, 184 rue du Faubourg Saint-Antoine, 75571, Paris cedex 12, France.
Background:
Capillary refill time (CRT) is a valuable tool for triage and to guide resuscitation. However, little is known about CRT kinetics after fluid infusion.
Methods:
We conducted a prospective observational study in a tertiary teaching hospital. First, we analyzed the intra-observer variability of CRT. Next, we monitored fingertip CRT in sepsis patients during volume expansion within the first 24 h of ICU admission. Fingertip CRT was measured every 2 min during 30 min following crystalloid infusion (500 mL over 15 min).
Results:
First, the accuracy of repetitive fingertip CRT measurements was evaluated on 40 critically ill patients. Reproducibility was excellent, with an intra-class correlation coefficient of 99.5% (CI 95% [99.3, 99.8]). A CRT variation larger than 0.2 s was considered as significant. Next, variations of CRT during volume expansion were evaluated on 29 septic patients; median SOFA score was 7 [5-9], median SAPS II was 57 [45-72], and ICU mortality rate was 24%. Twenty-three patients were responders as defined by a CRT decrease > 0.2 s at 30 min after volume expansion, and 6 were non-responders. Among responders, we observed that fingertip CRT quickly improved with a significant decrease at 6-8 min after start of crystalloid infusion, the maximal improvement being observed after 10-12 min (-0.7 [-0.3;-0.9] s) and maintained at 30 min. CRT variations significantly correlated with baseline CRT measurements (R = 0.39, P = 0.05).
Conclusions:
CRT quickly improved during volume expansion with a significant decrease 6-8 min after start of fluid infusion and a maximal drop at 10-12 min.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Urodynamic Studies: Uroflowmetry