Related Experiment Video
Updated: Sep 1, 2025

Visual Detection of Multiple Nucleic Acids in a Capillary Array
Published on: November 15, 2017
Super-assembly of integrated gold magnetic assay with loop-mediated isothermal amplification for point-of-care
Jianping Liang1, Jie Zeng2, Xiaojuan Huang1
1The College of life science, Northwest University, Xi'an, 710069 China.
Abstract:
With the increasing global threat of various diseases and infections, it is essential to develop a fast, low-cost, and easy-to-use point-of-care testing (POCT) system for inspections at all levels of medical institutions and self-examination at home. In this work, gold magnetic nanoparticles (GMNPs) are used as the key material, and a rapid visual detection method is designed through integrating loop-mediated isothermal amplification (LAMP) and lateral flow assay (LFA) biosensor for detecting a variety of analytes which includes whole blood, buccal swabs, and DNA. It is worth to note that the proposed method does not need DNA extraction. Furthermore, uracil DNA glycosylase (UDG) is employed to eliminate carrier contamination for preventing false positive results. The whole detection process can be finished within 25 min. The accuracy of detection is measured by assessing the polymorphisms of the methylenetetrahydrofolate reductase (MTHFR) C677T. The detection limit of the newly developed extraction-free detection system for MTHFR C677T is 0.16 ng/μL. A preliminary clinical study of the proposed method is carried out by analyzing 600 clinical samples (including 200 whole blood samples, 100 buccal swabs, and 300 genomic DNA samples). The results indicate that the proposed method is 100% consistent with the sequencing results which provides a new choice for POCT and shows a broad application prospect in all levels of medical clinics and at home.
Electronic Supplementary Material:
Supplementary material (details for MTHFR C677T primer sequences, the cell count results of samples at different dilution ratios, genotyping results and frequency samples, a Hardy-Weinberg equilibrium test, the sensitivity of the system, detection results of multiple samples, and optimization of the system) is available in the online version of this article at 10.1007/s12274-022-4692-9.
More Related Videos
06:18Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
09:58Computer Numerical Control Micromilling of a Microfluidic Acrylic Device with a Staggered Restriction for Magnetic Nanoparticle-Based Immunoassays
Published on: June 23, 2022