Dynamic navigation for dental implant placement in single-tooth gaps: A preclinical pilot investigation
Mats Wernfried Heinrich Böse1, Florian Beuer1, Andreas Schwitalla1
1Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité - Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Aßmannshauser Str. 4-6, Berlin 14197, Germany.
Objectives:
To compare the planned (PIP) and transferred implant position (TIP) after dental implant placement in single-tooth gaps utilizing dynamic computer-assisted implant surgery (dCAIS).
Methods:
Five pairs of artificial jaws (n = 5) with four single tooth gaps in FDI (Fédération Dentaire Internationale) regions 16, 25, 36 and 44 were manufactured via injection molding technique. Cone beam computed tomographies (CBCTs) were made and digital implant planning of twenty implants (n = 20) was performed with a dynamic navigation system (DNS, Navident, ClaroNav, Toronto, Canada). After guided drilling and manual implant placement, post-operative CBCTs were made. Global deviations at entry point (two-dimensional, 2D), apex (three-dimensional, 3D), apex (vertical, V) and angulation (in degrees, °) were calculated by DNS software. For statistical analysis, level of significance was set to p < 0.05.
Results:
Mean deviation at the implants entry point (2D) was 0.78 ± 0.45 mm (range: 0.10-1.63 mm). For the implants apex (3D) and the implants apex (V) deviations were 1.08 ± 0.50 mm (range: 0.33-2.10 mm) and 0.32 ± 0.22 mm (range: 0.02-0.90 mm), respectively. The median angular deviation (°) was 2.81 ± 2.29° (range: 0.56-9.58°). Statistically significant differences (p < 0.05) were found regarding apex (3D), apex (V), and angulation (°) comparing I.-IV. quadrants.
Conclusions:
Using the investigated dCAIS seems to provide satisfactory results regarding TIP in single-tooth gaps in vitro. Due to documented deviations, a safety distance of more than 2 mm should be respected while implant planning in DNS software.
Clinical Significance:
The investigated DNS seems to be reliant in transferring PIP with acceptable deviations in vitro.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
07:03Dynamic Navigation in Endodontics: Guided Access Cavity Preparation by Means of a Miniaturized Navigation System
Published on: May 5, 2022
Related Concept Videos
Tooth Anatomy
The Crown, Neck, and Root
The visible part of the tooth is referred to as the crown. It's covered by enamel, the hardest substance in the human body. The crown is uniquely shaped for each type of tooth, allowing for different functions such as cutting, tearing, or...
Teeth
In the bud stage, the tooth germ (an aggregation of cells) starts to form in the developing jawbone. During the cap stage, the tooth germ differentiates into enamel organ, dental papilla, and dental sac, which will later develop into the tooth's enamel, dentin...