Related Experiment Video
Updated: Aug 31, 2025

Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
Published on: May 6, 2014
High-resolution impedance manometry for comparing bolus transit between patients with non-obstructive dysphagia and
Boram Cha1, Kyungmin Choi2, Kee Wook Jung3
1Department of Internal Medicine, Digestive Disease Center, Inha University School of Medicine, Incheon, South Korea.
Background:
Currently, there are no high-resolution impedance manometry (HRIM)-based diagnostic criteria for non-obstructive dysphagia (NOD). New impedance parameters, such as the esophageal impedance integral (EII) and volume of inverted impedance (VII) ratios, have shown strong correlations with bolus transit. This study compared the EII and VII ratios as diagnostic tools for NOD.
Methods:
We analyzed 36 participants (12 patients with achalasia, 12 patients with NOD [7 with normal motility and 5 with ineffective esophageal motility], and 12 asymptomatic controls) who underwent HRIM with a maximum of 5 swallows per participant. The EII and VII ratios were calculated as Z2 (post-swallow)/Z1 (pre-swallow). Bolus transit was retrospectively evaluated using transluminal impedance analysis.
Key Results:
Both EII and VII ratios could effectively distinguish the achalasia group from the non-achalasia groups (area under the receiver operating characteristic curve [AUROC]: 0.83 for VII vs. 0.80 for EII; p = 0.73). However, the VII ratio was significantly better in discriminating asymptomatic controls from patients with dysphagia (NOD + achalasia) (AUROC: 0.81 vs. 0.68; p = 0.01). Moreover, the VII ratio was better in discriminating asymptomatic controls from patients with NOD (AUROC: 0.68 vs. 0.51; p = 0.06). In repeated swallows, the VII ratio was consistently the lowest in controls and the highest in patients with achalasia, whereas the EII ratio did not show a consistent pattern.
Conclusions & Inferences:
The VII ratio was more reliable than the EII ratio for describing bolus transit and distinguishing patients with NOD from asymptomatic controls, even during repeated measures of subsequent swallows.
Related Concept Videos
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...