Central arterial pressure and patient-specific model parameter estimation based on radial pressure measurements
Dániel Gyürki1, Tamás Horváth2, Sára Till1
1Department of Hydrodynamic Systems, Budapest University of Technology and Economics, Budapest, Hungary.
Abstract:
One-dimensional arterial flow simulations are suitable to estimate the aortic pressure from peripheral measurements in a patient-specific arterial network. This study introduces a reduction of the system parameters, and a novel calculation method to estimate the patient-specific set and the aortic curve based on radial applanation tonometry. Peripheral and aortic pressure curves were measured in patients, optimization were carried out. The aortic pressure curves were reproduced well, with an overestimation of the measured Systolic and Mean Blood Pressures on average by 0.6 and 0.5 mmHg respectively, and the Root Mean Square Difference of the curves was 3 mmHg on average.
More Related Videos
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation