Related Experiment Video
Updated: Aug 30, 2025

The Measurement of Unsteady Surface Pressure Using a Remote Microphone Probe
Published on: December 3, 2016
Relative Humidity Measurement of Air in Low-Temperature Ranges Using Low-Frequency Acoustic Waves and Correlation
Miao Guo1, Yue Li1, Jingmin Gao1
1School of Automation, Beijing Information Science and Technology University, Haidian District, Beijing 100192, China.
Abstract:
Air relative humidity (RH) is an important control parameter in many industrial processes. The acoustic method is a novel technique to measure air humidity non-intrusively. Relevant research is limited. Existing methods use ultrasonic waves as a sound source and air humidity is measured by measuring the sound attenuation. In this paper, a novel air humidity measurement system using low-frequency sound waves as a sound source and two acoustic sensors is proposed. Air humidity is acquired by measuring sound speed in the air. Sound speed mainly depends on air temperature, humidity, atmospheric pressure, and air composition. The influence of air temperature, atmospheric pressure, and air constituent concentrations on the RH measurement is analyzed theoretically. A 0.1 s linear chirp signal in the frequency range of 200-500 Hz is selected as the sound source. Sound travel time is calculated by cross-correlating the sound signals received by the two acoustic sensors. To improve the accuracy of the sound speed measurement, sound speed under different RH points is obtained through reference RH experiments and substituted into the calibration equation. Then, equivalent sound path length and systematic delay are estimated using the least squares method. After obtaining these two parameter values, the sound speed measured by the system is closer to the theoretical value at the same RH point. In validation experiments using RH measured by a thermo-hygrometer as a comparison, the relative errors of the acoustically measured RH are within 9.9% in the RH range of 40.7-87.1%, and the standard deviation is within 4.8%.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Measurement of Air Content in Concrete
The pressure method,...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...

