Related Experiment Video
Updated: Aug 30, 2025

Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
Investigation of the Fire Performance of Polyamide 6-Based Composites with Halogen-free Flame Retardants and
Tugce Uysalman1, Merve Sağlam1, Kerim Eraslan1
1İzmir Eğitim Sağlık Sanayi Yatırım A.Ş., Turgutlu 45400, Manisa, Turkey.
Abstract:
In this study, halogen-free flame retardants and metal synergist materials were used to enhance the flammability of PA6. PA6-based composites including various fractions of additives were manufactured using a twin-screw extruder and an injection molding machine. Mechanical, thermal, physical, morphological, and flame retardant properties were investigated with several characterization methods. The study aims to meet R22 requirements based on the EN45545 standard for fire protection of railway vehicles, according to which limiting oxygen index (LOI), smoke density, and conventional index of toxicity (CIT) values under HL3 hazard levels have to be min 32%, max 300, and max 1.5, respectively. 15FR-2MH, 15FR-5MH, 15FR-1MH-1ZB, 15FR-1MH-1BOH, and 15FR-1MH-1SIL composites exhibited both the required smoke density, CIT, and LOI values for R22. It can be said that hybrid synergists provide all requirements according to the R22-EN45545 standard. Instead of using 15FR-2MH, 15FR-1MH-1BOH led to a lower smoke density value for PA6.
Related Concept Videos
Flame Photometry: Overview
Flame Photometry: Lab
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene