The Accuracy and Reliability of Visually Assessed Pharyngeal Opening Pressures During Drug-Induced Sleep Endoscopy
Jason L Yu1,2, Eric Thuler1, Everett G Seay1
1Division of Sleep Surgery, Department of Otorhinolaryngology-Head and Neck Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Objective:
To examine the accuracy and interrater reliability of a visually assessed vs airflow-based measure of pharyngeal collapsibility obtained in patients with obstructive sleep apnea undergoing drug-induced sleep endoscopy (DISE).
Study Design:
Prospective observational study.
Setting:
Academic tertiary care practice.
Methods:
Patients underwent DISE with airflow monitoring and nasal positive airway pressure titration to determine visual and airflow-based levels of pharyngeal opening pressure (PhOP). Visual DISE-PhOP was assessed by 2 blinded independent raters and defined as the pressure at which visual confirmation of airway collapse, including snoring, was abolished. Airflow-based DISE-PhOP was defined as the minimally effective positive airway pressure that abolished inspiratory flow limitation. Equivalence testing between visual and airflow DISE-PhOP of each rater was performed with the two one sided T-test (TOST) with an a priori equivalence bound of ±1 cm H2 O. Interrater reliability was evaluated with the intraclass correlation coefficient.
Results:
One hundred patients were enrolled in the study and 77 completed the full evaluation. The population was predominantly male (74%) with an average age of 54.8 years, body mass index of 30.1 kg/m2 , and apnea-hypopnea index of 30.7 events/h. Equivalence testing showed that both raters were within ±1 cm H2 O of airflow-based DISE-PhOP (-0.43 to 0.09 cm H2 O and -0.32 to 0.48 cm H2 O). Interrater reliability of visual DISE-PhOP between the raters was also good to excellent with an intraclass correlation coefficient of 0.895 (95% CI, 0.84-0.932).
Conclusion:
DISE-PhOP, a measure of upper airway collapsibility, was equivalent between airflow-based and visual assessments with strong interrater reliability, supporting its adoption as a standardized objective parameter in clinical DISE.