Related Experiment Video
Updated: Aug 30, 2025

Assessment of the Efficacy of An Osteopathic Treatment in Infants with Biomechanical Impairments to Suckling
Published on: February 5, 2019
Utility of the One-time HACOR Score as a Predictor of Weaning Failure from Mechanical Ventilation: A Prospective
Souvik Chaudhuri1, Nitin Gupta2, Shreya Das Adhikari3
1Department of Critical Care Medicine, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India.
Aim:
To determine the utility of the HACOR score in predicting weaning failure in resource-limited settings.
Objectives:
The primary objective was to determine a cut-off value of the HACOR score, sensitivity, and specificity to predict failed weaning. The secondary objective was to determine which out of five components of the score was significantly different between the successful weaning and the failed weaning groups.
Introduction:
Most weaning indices are either inaccurate or are dependent on complex ventilatory parameters, which are difficult to measure in resource-limited settings. This study aimed to determine the utility of the HACOR score consisting of heart rate, acidosis, consciousness level, oxygenation, and respiratory rate as a predictor of weaning in the intensive care unit.
Materials And Methods:
It was a prospective observational study on 120 patients between 18 and 90 years. The HACOR score was evaluated at 30 minutes of spontaneous breathing trial (SBT). The total duration of SBT was 120 minutes.
Results:
Out of 120 patients, 83 (69.2%) had successful weaning, whereas 37 (30.8%) had weaning failure. The median and interquartile range (IQR) of the HACOR score in the successful weaning group was 2 (0-3) and 6 (5-8) in the failed weaning group (p-value <0.001). There was a significant difference in each of the five components of the HACOR score between the successful and failed weaning groups (p <0.05). HACOR score ≥5 predicted failed weaning, sensitivity 83.8%, specificity 96.4%, area under the curve (AUC) 0.950, and 95% confidence interval (CI) [0.907-0.993], p <0.001. Multivariable logistic regression analysis showed that HACOR score ≥5 is an independent predictor of weaning failure [p <0.001, 95% CI (1.9-4.2), adjusted odds ratio 2.82].
Conclusion:
A HACOR score ≥5 is an excellent predictor of weaning failure. This score may be useful as a weaning strategy in the intensive care unit.
How To Cite This Article:
Chaudhuri S, Gupta N, Adhikari SD, Todur P, Maddani SS, Rao S. Utility of the One-time HACOR Score as a Predictor of Weaning Failure from Mechanical Ventilation: A Prospective Observational Study. Indian J Crit Care Med 2022;26(8):900-905.
Ethical Approval:
Prior to the commencement of the study, Institutional Ethics Committee permission was obtained (IEC: 197/2021) and Clinical Trial Registry of India (CTRI) registration was done before recruitment (CTRI/2021/07/035139). We obtained written informed consent from the legally authorized representative prior to recruiting patients for the study.
More Related Videos
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III