Related Experiment Video
Updated: Aug 30, 2025

Diagnosis of Neoplasia in Barrett’s Esophagus using Vital-dye Enhanced Fluorescence Imaging
Published on: May 11, 2014
Which Videofluoroscopy Parameters Are Susceptible to the Influence of Differences in Barium Product and
Catriona M Steele1,2, Emily Barrett1, Melanie Peladeau-Pigeon1
1Swallowing Rehabilitation Research Laboratory, KITE Research Institute, Toronto Rehabilitation Institute - University Health Network, Ontario, Canada.
Purpose:
Prior studies suggest there may be differences in videofluoroscopic measures of swallowing across different barium concentrations. Whether different barium products of identical concentration result in similar swallowing physiology remains unknown. This is important, as barium intended for videofluoroscopy (i.e., Bracco Varibar) is not available globally. Our aim was to identify differences in healthy swallowing across five different barium stimuli.
Method:
Twenty healthy adults (10 women), aged 22-54 years, underwent videofluoroscopy including comfortable sips of thin liquid barium: two sips of 20% weight-to-volume (w/v) barium prepared with E-Z-HD powder, and two sips each of 20%w/v and 40%w/v barium prepared with Liquid Polibar Plus and E-Z-Paque powder. Recordings were analyzed according to the Analysis of Swallowing Physiology: Events, Kinematics and Timing Method. Measures of timing, kinematics and residue were obtained. Chi-square, Friedman's, and Wilcoxon signed-ranks test were used to identify differences across stimuli.
Results:
Significant differences were seen across barium stimuli for upper esophageal sphincter (UES) opening duration, UES diameter, pharyngeal area at maximum constriction, and residue. In all cases, smaller values were seen with the 20%w/v E-Z-HD stimulus; however, this stimulus had questionable opacity for visualization. Patterns of residue severity were not explained by barium concentration.
Conclusions:
This study confirms that some measures of swallowing are influenced by barium product and/or concentration. Measures are not necessarily similar across different barium products at the same concentration. This study illustrates the importance of using standard and appropriate stimuli in videofluoroscopy, and for clinicians to report not only the product but also the concentration of stimuli used.
Supplemental Material:
https://doi.org/10.23641/asha.20669712.
Related Concept Videos
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Computed Tomography
Variables Affecting Phosphorescence and Fluorescence