Indirect Method for Estimation of Reference Intervals of Inflammatory Markers
Taewon Kang1, Jeaeun Yoo2, Dong Wook Jekarl1,3
1Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
The indirect method for reference interval (RI) estimation effectively determined RIs for inflammatory biomarkers like C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR), offering a viable alternative to direct methods.
Area of Science:
- Clinical Chemistry
- Biomarker Analysis
- Statistical Modeling
Background:
- Direct reference interval (RI) estimation faces challenges including resource demands, defining non-diseased populations, and ethical sample acquisition.
- The indirect method for RI estimation (RII) presents an alternative approach to overcome these limitations.
Purpose of the Study:
- To estimate reference intervals (RIs) for inflammatory biomarkers using an indirect method (RII).
- To evaluate the influence of measurement size and data characteristics on the accuracy of RII.
Main Methods:
- Retrieved C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), and presepsin (PSEP) data from a single hospital (April 2009-April 2021).
- Applied Box-Cox transformation for right-skewed data and latent profile analysis to model mixed non-diseased and diseased populations.
- Estimated RIs at the intersection point of distribution curves and evaluated measurement size influence.
Main Results:
- Estimated RIs using RII: CRP 0-4.1 mg/L, ESR 0-10.2 mm/hr, PSEP 0-411 pg/mL.
- Stable results were observed for measurement sizes ≥2,500.
- An abnormal-to-normal value ratio of 0.5 yielded the most accurate CRP results, with specific adjustment values for different measurement sizes.
Conclusions:
- The proposed indirect method (RII) offers a valuable approach for reference interval verification and estimation.
- The RII method provides additional insights, though some limitations should be considered.