Efficient simulation of resonance Raman spectra with tight-binding approximations to density functional theory
Sahar Ashtari-Jafari1, Zahra Jamshidi2, Lucas Visscher3
1Chemistry & Chemical Engineering Research, Center of Iran (CCERCI), Pajohesh Blvd., 17th Km of Tehran-Karaj Highway, P.O. Box 1496813151, Tehran, Iran.
Abstract:
Resonance Raman spectroscopy has long been established as one of the most sensitive techniques for detection, structure characterization, and probing the excited-state dynamics of biochemical systems. However, the analysis of resonance Raman spectra is much facilitated when measurements are accompanied by Density Functional Theory (DFT) calculations that are expensive for large biomolecules. In this work, resonance Raman spectra are therefore computed with the Density Functional Tight-Binding (DFTB) method in the time-dependent excited-state gradient approximation. To test the accuracy of the tight-binding approximations, this method is first applied to typical resonance Raman benchmark molecules, such as β-carotene, and compared to results obtained with pure and range-separated exchange-correlation functionals. We then demonstrate the efficiency of the approach by considering a computationally challenging heme variation. Overall, we find that the vibrational frequencies and excited-state properties (energies and gradients) that are needed to simulate the spectra are reasonably accurate and suitable for interpretation of experiments. We can therefore recommend DFTB as a fast computational method to interpret resonance Raman spectra.
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Resonance and Hybrid Structures
Resonance Structures and Resonance Hybrids
The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N–O and N=O bonds.
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
NMR Spectrometers: Resolution and Error Correction
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...